background image

VA-C_man rev01-2016_VI_(uk) | 1.02.2017

 6

WARNING

PLASTIC PARTS CLEANING SOLVENT HAzARD
Use only compatible water-based solvents to clean plastic structural or pressure-
containing parts. Many solvents can degrade plastic parts and cause them to fail, 
which could cause serious injury or property damage. See Technical Data in this 

and all other equipment instruction manuals. Read fluid and solvent manufacturer’s 

warnings.

TOXIC FLuID OR FumES HAzARD

Toxic fluids or fumes can cause serious injury or death if splashed

 

in the eyes or on skin, inhaled, or swallowed.

  

Read MSDS’s to know the specific hazards of the fluids you are using.

  Route exhaust away from work area. If diaphragm ruptures, 

fluid may be exhausted with air.

  

Store hazardous fluid in approved containers, and dispose of it according 

 

to applicable guidelines.

  Always wear impervious gloves when cleaning equipment.

BuRN HAzARD

Equipment surfaces and fluid that’s heated can become very hot during operation. 

To avoid severe burns:

  

Do not touch hot fluid or equipment.

  

Wait until equipment/fluid has cooled completely.

PERSONAL PROTECTIVE EQuIPmENT
You must wear appropriate protective equipment when operating, servicing,  
or when in the operating area of the equipment to help protect you from serious 
injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss.  
This equipment includes but is not limited to:

  Protective eyewear, gloves, and hearing protection

  Protective clothing

Содержание VERDERAIR CONT-EX VA-C10

Страница 1: ...Find you local supplier at www verderair com or scan the QR code VA C_man_Rev01 2016_VI_ uk Solid machined air operated diaphragm pumps VERDERAIR CONT EX ...

Страница 2: ...x Warnings Installation Operation Maintenance repair Trouble shooting Parts and kits Torque Values Exploded views Dimensions and mounting Performance charts Technical data Customer services guarantee 3 4 5 7 10 11 16 17 17 18 20 21 23 24 TABLE OF CONTENTS ...

Страница 3: ... parts of the pump are compatible to the pumped liquid Note In case of doubt please contact your local supplier www verderair com To build a pump code please use the below coding system or use the pump configurator on www verderair com PUMP CODING VA C Pump size Housing and center section valve material Diaphragm material 10 3 8 GG Conductive Polyethylene TF PTFE ball valve TO PTFE overmolded 20 1...

Страница 4: ...ific warnings may be found throughout the body of this manual where applicable Fire and explosion Hazard Flammable fumes such as solvent and paint fumes in work area can ignite or explode To help prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static arc Ke...

Страница 5: ...se equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations PRESSURIZED EQUIPMENT HAZARD Fluid from dispense valve leaks or ruptured com...

Страница 6: ... using Route exhaust away from work area If diaphragm ruptures fluid may be exhausted with air Store hazardous fluid in approved containers and dispose of it according to applicable guidelines Always wear impervious gloves when cleaning equipment BURN HAZARD Equipment surfaces and fluid that s heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment Wai...

Страница 7: ...dismantling of the pump and after periods when the pump hasn t been working the stops plugs and housing bolts have to be checked For the housing bolts please use the torque values as mentioned on page 22 Figure 1 showing the installation of the pump A Air Control pro unit consists of On of valve Pressure regulator Throttle valve Soft start valve B Isolating valve C Discharge gauge D Suction gauge ...

Страница 8: ...e codes When pumping flammable fluids always ground the entire fluid system as described Air Line See recommended installation drawing on page 7 1 Install an air regulator and gauge Set pressure of the driving air should be limited to the pressure required to run the pump on the desired working point Setting the pressure too high will cause higher wear of the pump and will increase the compressed ...

Страница 9: ...pump to isolate the pump from the system for maintenance and installation A drain valve should be installed to relief the pressure of the pump before starting maintenance work at the pump 2 Always use a flexible connection to avoid vibrations being brought into the piping system Fluid inlet and outlet ports VA C series of pump are having the suction and discharge connections integrated in the cent...

Страница 10: ...o relieve fluid pressure Have a container ready to catch the drainage Flush pump before first use The pump was tested before leaving the factory Residue of the testing water can be left in the pump To avoid contamination flush the pump before first use Starting and adjusting the pump 1 Be sure the pump is properly grounded See page 8 for proper grounding 2 Check fittings to be sure they are tight ...

Страница 11: ...cedure on page 10 before storing it for any length of time Use a compatible flushing agent Tightening Threaded connections Before each use check all hoses for wear or damage and replace as necessary Check to be sure all threaded connections are tight and leak free Tighten and retorque the pump if necessary Use torque values on page 22 Preventive maintenance schedule Establish a preventive maintena...

Страница 12: ...lve balls or cylindrical valves To have access to the valve seats and balls you need to disassemble the pump side housings first Unscrew the liquid plug 09 at the top of the side housing 02 03 with the special tool see Figure 7 1 and 7 2 Figure 5 Figure 6 22 1 2 1 3 4 Figure 4 Figure 7 1 Figure 7 2 Figure 8 9 12 2 9 2 2 Plug tool Plug tool Remove housing o rings 22 Remove discharge valve ball or d...

Страница 13: ...ly Before starting to assemble please check all parts on possible damages Especially the sealing area of the diaphragms have to be free from scratches see Figure 12 Assembly of the centre housing Remove the end caps the main valve and the air valve shaft out of the the air valve 27 Screw one end cap flush into the centre housing 01 by using the special tool see Figure 11 Put 1 off the six air valv...

Страница 14: ...tion of the holes for the assembly pins by turning one of the diaphragms a little backwards Assembly of the housing Place O rings 22 into side sections 2 and 3 Place the valve ball 11 or the cylindrical valve 10 in to the side section integrated suction seat see Figure 16 1 place valve seat 12 in to side section and pay attention that valve seat flow bore will be in the center with internal channe...

Страница 15: ...s and put the bolts on Fasten the bolts crosswise up to the torque values as mentioned on page 22 Always test the pump on leakages before using it Figure 17 Figure 16 3 Figure 16 5 Figure 16 2 Figure 16 4 14 23 Figure 16 1 Align both holes Assemble plug flush with side housing ...

Страница 16: ...ainer empty Cavitation Tighten Replace the diaphragms and clean the pump Fill or replace suction container Check suction condition and adapt when necessary Fluid in exhaust air Diaphragm rupture Replace the diaphragms and clean the pump Insufficient discharge pressure Not enough air pressure Air supply is leaking Check valves worn Air valve is leaking Increase compressed air pressure or check if n...

Страница 17: ...hragm 17 O ring valve plug Shaft seal 20 only VA C50 and VA C130 Muffler 7 Air valve 27 4 4 2 2 2 1 1 Please check the seperate spare parts list for the order nr for the kit you need for your pump SEE SEPERATE PARTS LIST Torque values for housing bolts assembly in Nm Device model VA C10 VA C20 VA C50 VA C130 all models 3 4 6 8 Torque values for housing bolts assembly in inlb Device model VA C10 VA...

Страница 18: ... 22 Pos N Description Quantity needed 1 CENTER HOUSING 1 2 SIDE HOUSING RIGHT 1 3 SIDE HOUSING LEFT 1 6 SHOCK ABSORBER 4 7 MUFFLER 1 9 VALVE PLUG 2 10 CYLINDER VALVE 4 11 VALVE BALL 4 12 VALVE SEAT 2 14 O RING SET VALVE PLUG 1 17 DIAPHRAGM 2 22 O RING SET HOUSING 1 23 ASSEMBLY PIN SET 4 27 AIR VALVE 1 ...

Страница 19: ...ntity needed 1 CENTER HOUSING 1 2 SIDE HOUSING RIGHT 1 3 SIDE HOUSING LEFT 1 6 SHOCK ABSORBER 4 7 MUFFLER 1 9 VALVE PLUG 2 10 CYLINDER VALVE 4 11 VALVE BALL 4 12 VALVE SEAT 2 14 O RING SET VALVE PLUG 1 17 DIAPHRAGM 2 18 DIAPHRAGM SHAFT SCREW 2 19 SHAFT 1 20 BEARING SET SHAFT 1 22 O RING SET HOUSING 1 23 ASSEMBLY PIN SET 6 27 AIR VALVE 1 ...

Страница 20: ...53 19 19 17 101 VA C50 180 172 197 NPT 3 4 R 1 4 150 75 27 23 17 145 VA C130 246 223 259 NPT 1 1 2 R 1 4 215 100 37 33 17 200 Type A B C G H M N O Q R S VA C10 3 54 3 70 5 20 NPT f 3 8 R 1 4 2 80 1 61 0 55 0 59 0 31 3 86 VA C20 5 12 5 04 5 91 NPT f 1 2 R 1 4 3 94 2 09 0 75 0 75 0 67 3 98 VA C50 7 09 6 77 7 76 NPT f 3 4 R 1 4 5 91 2 95 1 06 0 91 0 67 5 71 VA C130 9 69 8 78 10 20 NPT f 1 1 2 R 1 4 8...

Страница 21: ...3 0 4 0 5 0 6 0 7 0 8 0 25 Nm3 min 0 1 Nm3 min 0 05 Nm3 min Liquid flow m3 h Gpm 0 0 44 0 88 1 32 1 76 2 20 2 64 3 08 3 52 102 87 73 58 44 29 15 0 102 87 73 58 44 29 15 0 5 45 SCFM 3 5 SCFM 1 85 SCFM 0 0 2 0 4 0 6 0 8 1 1 2 1 4 Liquid flow m3 h Gpm 0 20 Nm3 min 0 15 Nm3 min 0 10 Nm3 min 0 05 Nm3 min 0 0 88 1 76 2 64 3 52 4 40 5 28 6 16 7 1 SCFM 5 3 SCFM 3 5 SCFM 1 8 SCFM ...

Страница 22: ... Gpm 0 15 Nm3 min 0 25 Nm3 min 0 35 Nm3 min 0 2 20 4 40 6 60 8 81 11 05 13 21 15 41 17 61 102 87 73 58 44 29 15 0 102 87 73 58 44 29 15 0 5 34 SCFM 8 8 SCFM 12 4 SCFM 0 1 2 3 4 5 6 7 Liquid flow m3 h Gpm 0 1 Nm3 min 0 3 Nm3 min 0 4 Nm3 min 0 5 Nm3 min 0 2 Nm3 min 0 4 40 8 81 13 21 17 61 22 01 26 42 30 82 3 5 SCFM 10 65 SCFM 14 1 SCFM 17 7 SCFM 7 1 SCFM VA C50 VA C130 ...

Страница 23: ... 9 Max operating pressure bar 7 7 7 7 Max operating temperature C 70 70 70 70 US measurements Device model VA C10 VA C20 VA C50 VA C130 Nominal port size NPT 3 8 1 2 3 4 1 1 4 Air connection R 1 4 R 1 4 R 1 4 R 1 4 Weight lbs 2 87 4 85 7 05 9 26 Suction lift dry max fwc with cylinder valves 2 3 6 56 11 48 13 78 with ball valves 1 64 1 64 6 56 8 2 Suction lift wet max fwc 26 25 26 25 29 53 29 53 Ma...

Страница 24: ...n all events is limited and shall not exceed the purchase price Warranty disclaimer Verder has made an effort to illustrate and describe the products accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the products are merchantable or fit for a particular purpose or that the products will necessarily conform ...

Отзывы: