819.6247
5
Installation
Mountings
Caution
The pump exhaust air may contain contaminants. If needed,
ventilate to a remote area to reduce possible fluid contamina-
tion. See
Air Exhaust Ventilation
on page 4.
Be sure the mounting can support the weight of the
pump, hoses, and accessories, as well as the stress
caused during operation.
For all mountings, be sure the pump is secured with
screws and nuts.
Warning
To reduce the risk of serious injury, splashing in the eyes
or on the skin, and toxic fluid spills,
never
move or lift a
pump under pressure. If dropped, the fluid section may
rupture. Always follow the
Pressure Relief Procedure
on
page 7 before you move or lift the pump.
Air Lines
Warning
Bleed-Type Master Air Valve and Fluid Drain Valve
A bleed-type master air valve and a fluid drain valve are
required on your system.
The bleed-type master air valve relieves air trapped be-
tween itself and the pump. Trapped air can cause the
pump to cycle unexpectedly, which could result in serious
bodily injury, including splashing in the eyes, injury from
moving parts, or contamination from hazardous fluids.
The fluid drain valve reduces the risk of serious bodily
injury, including splashing in the eyes or on the skin, or
contamination from hazardous fluids. Install the fluid drain
valve close to the pump’s fluid outlet to relieve pressure in
the hose if the hose becomes plugged.
1.
Mount the air line accessories on the wall or on a
bracket. Be sure the air line supplying the accessories
is grounded.
a.
The pump speed can be controlled in one of two
ways: To control it on the air side, install an air
regulator. To control it on the fluid side, install a
fluid valve near the outlet.
b.
Install a bleed-type master air valve downstream
from the air regulator, and use it to relieve trapped
air. See the
Bleed-Type Master Air Valve and
Fluid Drain Valve
warning at left. Locate another
bleed-type master air valve upstream from all air line
accessories, and use it to isolate the accessories
during cleaning and repair.
c.
The air line filter removes harmful dirt and moisture
from the compressed air supply.
2.
Install a flexible air hose between the accessories and
the pump air inlet. Screw the air line fitting into the air
inlet.
3.
Do not restrict the exhaust port. Excessive exhaust
restriction can cause erratic pump operation.
Fluid Lines
Fig. 2. On each end of the fluid manifold are a fluid IN port
and a fluid OUT port.
NOTE: Make sure the fluid OUT port
on the fluid manifold is mounted up.
This will insure proper
pump priming.
Fluid-in
and
fluid-out
lines can be connected
on the same end, or opposite ends of the manifold. Plug
ports that are not used (plugs provided).
Fig. 2
06179A