![Verdant VX Series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/verdant/vx-series/vx-series_installation-manual_1003554045.webp)
W
O/B
Y
45
Relay Options
1 – REVERSE RELAY OPERATION
Select Relay Operation for Y, W, O/B outputs:
C *
NORMALLY CLOSED - Thermostat activates the relay to
energize the output when there is a call for it; Output is not
energized when idle.
O
NORMALLY OPEN - Thermostat de-activates the relay to
de-energize the output when there is a call for it; Output is
energized when idle.
*
Indicates default setting;
➤
Use the “Up” and “Down” buttons to change the setting value;
➤
Press the “Fan” button to go to the next setting on the screen;
➤
Press the “F/C” button to go to the next setting screen;
➤
Press the “Power” button to save and exit thermostat settings;
Содержание VX Series
Страница 1: ...V VX Series Thermostat with an Occupancy Sensor INSTALLATION MANUAL V 5 MAY 31 2016 ...
Страница 2: ......
Страница 6: ...6 ...