![Veratron B00070501 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/veratron/b00070501/b00070501_user-manual_1003221007.webp)
SYSTEM INSTALLATION
B001032
CONNECT TO THE NMEA2000® NETWORK
Connect the sensor and the LinkUp gateway with the 3-pin connector
(Hirschmann 3way 1.2 SealStar FA Connector).
Now interface the LinkUp gateway to the NMEA 2000® backbone
through the dedicated plug.
Please ensure to tighten the M12 connector by screwing it onto its
counterpart, so to preserve the water tightness.
A drop cable is not needed unless the total length of the LinkUp
device is not enough to reach the NMEA 2000® backbone. In this
case it is possible to extend the total length by using one of the
accessory drop cables.
Please note that NMEA 2000® does not allow drop cables longer
than 6 meters.
Refer to the NMEA 2000® standard for a proper network design.
If power from the NMEA 2000® network is received, the green LED
on the LinkUp housing will start flashing (see “LED notifications”).
Содержание B00070501
Страница 1: ...B001032 LINK UP GATEWAYS SERIES LINK UP 2 in 1 USER MANUAL rev AB DE EN IT FR ES PT...
Страница 12: ...TECHNICAL DATA B001032 DIMENSIONS...
Страница 15: ...B001032 LINK UP GATEWAYS SERIES LINK UP 2 in 1 BEDIENUNGSANLEITUNG rev AB DE EN IT FR ES PT...
Страница 27: ...TECHNISCHE DATEN B001032 ABMESSUNGEN...