Veratron B00070501 Скачать руководство пользователя страница 3

INTRODUCTION 

B001032 

INTRODUCTION 

 

PACKAGING CONTENT 

 

 

 

 

LinkUp Gateway

 

B00070501 
Interfaces the 2-in-1 Temperature & Pressure Sensor with 
the NMEA 2000® network to make all the information 
available for any display. 
Wireless configurable, the LinkUp gateway can be easily set 
up with your smartphone and the LinkUp configurator App.

 

 

 
 
 

 

 

 

Combined Oil Pressure and Temperature Sensor 

B000843 
Measures the transmission- or engine oils temperature and 
pressure while providing the data to the LinkUp, which 
translates it to the NMEA 2000® standard. 

 

THE LINKUP GATEWAY CONCEPT

 

The 2-in-1-type LinkUp gateway provides an easy method to convert engine information to NMEA 2000. 

The devise is designed to fit one specific sensor. This sensor measures temperature and pressure. It can be 
applied for engine- or transmission oil. 

Easily installed, the LinkUp gateway replaces the original wiring, delivering power to both the LinkUp device 
and sensor from the NMEA 2000 backbone while still being compliant with the NMEA 2000 certification 
requirements. 

The data are then available for being displayed on any VMH, OceanLink, AcquaLink, or more in general on 
any glass cockpit NMEA 2000 display device. 

Configuring LinkUp gateways is simple, using a mobile device and the companion LinkUp Configurator App 
which is available for free for Android and iOS. Each device has a built-in passive NFC antenna, so the 
parameters of the sensor are wirelessly configured to type, instance and warning threshold on the mobile 
device which is then “tapped” against the LinkUp device for instant data download. 

 

DESIGN AND FUNCTION

  

The LinkUp gateway has a simple but yet effective design.  

The potted housing allows the unit to be installed in engine rooms, making it compliant to the ISO 
8846:1990 as requested by the directive 2013-53(EC). 

The standard NMEA 2000® M12 plug allows for a plug-and-play installation to the network backbone. 

The sensor connection happens through a Hirschmann 3way 1.2 SealStar FA Connector, which perfectly 
matches the Veratron 2-in-1 sensor, without the need of additional wiring. 

Содержание B00070501

Страница 1: ...B001032 LINK UP GATEWAYS SERIES LINK UP 2 in 1 USER MANUAL rev AB DE EN IT FR ES PT...

Страница 2: ...During Installation 4 Safety After Installation 5 Electrical Connection 5 System Installation 6 Before the Assembly 6 Connect to the NMEA2000 Network 7 Configuration 8 Link Up Configurator App 8 Senso...

Страница 3: ...the NMEA 2000 backbone while still being compliant with the NMEA 2000 certification requirements The data are then available for being displayed on any VMH OceanLink AcquaLink or more in general on an...

Страница 4: ...Avoid damaging these components Only install undamaged parts in a vehicle During installation ensure that the product does not impair the field of vision and that it cannot impact the driver s or pas...

Страница 5: ...ectrical cables use the provided cable ducts and harnesses however do not run cables parallel to ignition cables or to cables that lead to large electricity consumers Fasten cables with cable ties or...

Страница 6: ...fires battery explosions and damages to other electronic systems Please note that when you disconnect the battery all volatile electronic memories lose their input values and must be reprogrammed BEFO...

Страница 7: ...counterpart so to preserve the water tightness A drop cable is not needed unless the total length of the LinkUp device is not enough to reach the NMEA 2000 backbone In this case it is possible to exte...

Страница 8: ...and detailed explanation of the configuration process is also available as in app instructions Thanks to the passive embedded NFC receiver the LinkUp gateway can be configured as described below witho...

Страница 9: ...ose the engine instance so that the LinkUp gateway will correctly transmit the data over NMEA 2000 4 Now you can decide whether you want the alarms enabled or not and at which value these alarms shoul...

Страница 10: ...1Hz Device in operation with invalid or empty configuration Waiting for configuration by the user factory setting NMEA 2000 messages are NOT transmitted Fast blink 5Hz Analogue value from the sensor o...

Страница 11: ...ammability UL94 HB Sensor cable length 90 cm NMEA 2000 cable length 25 cm NMEA 2000 plug DeviceNet Micro C M12 5 pins Male SENSOR DATASHEET Operating voltage 4 75 5 25V Provided by the LinkUp Output S...

Страница 12: ...TECHNICAL DATA B001032 DIMENSIONS...

Страница 13: ...C M12 5 poles plug Male product side view Pin No Wire color Description 1 Red Power 5V Provided by the LinkUp 2 Black GND 3 Green PWM output Sensor plug Female product side view SUPPORTED NMEA 2000 P...

Страница 14: ...ing from veratron AG except for the following actions Printing the document in its original format totally or partially Copying contents without any modifications and stating Veratron AG as copyright...

Страница 15: ...B001032 LINK UP GATEWAYS SERIES LINK UP 2 in 1 BEDIENUNGSANLEITUNG rev AB DE EN IT FR ES PT...

Страница 16: ...chten 4 Nach dem Einbau beachten 5 Elektrischer Anschluss 6 Installation des Systems 7 Vor der Installation 7 Anschluss an das NMEA2000 Netzwerk 8 Konfiguration 9 Link Up Configurator App 9 Sensor Kon...

Страница 17: ...ne w hrend es gleichzeitig die Anforderungen der NMEA 2000 Zertifizierung erf llt Die Daten k nnen dann auf jedem VMH OceanLink AcquaLink oder generell auf jedem NMEA 2000 Display im Glascockpit angez...

Страница 18: ...n am VDO Produkt k nnen die Sicherheit beeinflussen Es darf deshalb nicht ver ndert oder manipuliert werden Beim Aus Einbau von Sitzen Abdeckungen o darauf achten dass Sie keine Leitungen besch digen...

Страница 19: ...nenfalls vergr ssern und fertig stellen Kanten entgraten Unbedingt die Sicherheitshinweise der Handwerkzeughersteller beachten Bei notwendigen Arbeiten ohne Spannungsunterbrechung darf nur mit isolier...

Страница 20: ...e Litzen besch digt oder abgetrennt werden Verl ten Sie neu zu schaffende Kabelverbindungen nur im Weichl tverfahren oder verwenden Sie handels bliche Krimpverbinder Nehmen Sie Krimpverbindungen nur m...

Страница 21: ...nischen Systemen verursachen Bitte beachten Sie dass beim Abklemmen der Batterie alle fl chtigen elektronischen Speicher ihre eingegebenen Werte verlieren und neu programmiert werden m ssen VOR DER IN...

Страница 22: ...garantiert werden kann Ein Verbindungskabel wird nicht ben tigt es sei denn die Gesamtl nge des LinkUp Ger ts reicht nicht aus um den NMEA 2000 Backbone zu erreichen In diesem Fall ist es m glich die...

Страница 23: ...kl rung des Konfigurationsprozesses ist auch als In App Anleitung verf gbar Dank des passiven eingebetteten NFC Empf ngers kann das LinkUp Gateway wie unten beschrieben ohne Stromversorgung konfigurie...

Страница 24: ...s LinkUp Gateway die Daten korrekt ber NMEA 2000 bertragen kann 4 Nun k nnen Sie entscheiden ob Sie die Alarme aktivieren wollen oder nicht und bei welchem Wert diese Alarme ausgel st werden sollen So...

Страница 25: ...n Betrieb mit ung ltiger oder leerer Konfiguration Wartet auf die Konfiguration durch den Benutzer Werkseinstellung NMEA 2000 Meldungen werden NICHT bertragen Schnelles Blinken 2Hz Analogwert vom Sens...

Страница 26: ...rkeit UL94 HB L nge des Sensorkabels 90 cm NMEA 2000 Kabell nge 25 cm NMEA 2000 Stecker DeviceNet Micro C M12 5 Pins Stecker SENSOR DATENBLATT Betriebsspannung 4 75 5 25V wird vom LinkUp bereitgestell...

Страница 27: ...TECHNISCHE DATEN B001032 ABMESSUNGEN...

Страница 28: ...M nnlich Produktseitige Ansicht Pin Nr Farbe des Kabels Beschreibung 1 Rot Stromversorgung 5V wird vom LinkUp bereitgestellt 2 Schwarz Masse 3 Gr n PWM Ausgang Sensor Stecker Weiblich Produktseitige...

Страница 29: ...Ausnahme der folgenden Massnahmen Drucken des Dokuments in seinem urspr nglichen Format ganz oder teilweise Kopieren von Inhalten ohne nderungen und unter Angabe der Veratron AG als Urheber Veratron A...