7 MAINTENANCE
BATTERY REPLACEMENT
When low battery indicator “
” is displayed in Out or CH section of the LCD display, it
indicates that the wireless 7-in-1 or current channel sensor battery power give wireless sensor
shown is low respectively. Please replace with new batteries.
WIRELESS 7-IN-1 SENSOR MAINTENANCE
REPLACE THE WIND VANE
Unscrew and remove the wind
vane for replacement
REPLACE THE WIND CUP
1. Remove rubber cap and Unscrew
2.
Remove the wind cup for
replacement
CLEANING THE RAIN COLLECTOR
1. Rotate the rain collector by turning it
30°anti-clockwise.
2.
Gently remove the rain collector.
3. Clean and remove any debris or
insects.
4.
Install the collector when it is clean
and fully dried.
CLEANING THE UV SENSOR AND
CALIBRATION
•
For precision UV measurement,
gentle clean the UV sensor cover
lens with damp micro-fiber cloth.
•
Over time, the UV sensor will
naturally degrade. The UV sensor
can be calibrated with a utility
grade UV meter, please refer to
Calibration section in previous page
for about the UV sensor calibration.
CLEANING HYGRO-THERMO
SENSOR
1. Remove the 2 screws at the bottom
of the radiation shield.
2.
Gently pull out the bottom 4 shields.
3. Carefully remove any dirt or insects
on the sensor (do not let the sensors
inside get wet).
4.
Clean the shield with water to
remove any dirt or insects.
5.
Install all the parts back when they
are clean and fully dried.
8 TROUBLESHOOT
Problems
Solution
Strange or no measurement
of Rain Sensor
1.
Check the drain hole in the rain collector.
2. Check the balance indicator.
Strange or no measurement
of Thermo / Hygro Sensor
1.
Check the radiation shield.
2. Check the sensor casing.
Strange or no measurement
of Wind Speed and Direction
1. Check wind cups (Anemometer).
2.
Check the wind vane.
and
(Signal lost for 15
minutes)
and
(Signal lost for 1
hour)
1. Relocate the console and 7-IN-1 sensor closer to each
other.
2.
Make sure the console is placed away from other
electronic Appliances that may interfere with the wireless
communication (TVs, computers, microwaves).
3. If problem continues, reset both console and 7-IN-1
sensor.
Out temperature reading too
high in the day time
Make certain that the sensor array is not too close to
heat generating sources or structures, such as buildings,
pavement, walls or air conditioning units.
24
Содержание 5705858718910
Страница 58: ...Smart 7 i 1 vejrstation med professionel sensor Model W838 Brugervejledning Smartphone medf lger ikke 1...
Страница 85: ...28...
Страница 86: ...29...
Страница 87: ...30...
Страница 88: ......