background image

2

Technical information

2.1 General definition

The IDEO 275 Ecowatt provides optimum ventilation for a room with a minimum loss of energy. It 
extracts air from spaces such as (Bathroom/s WC kitchen and washroom/s or shower room/s and

extracts air from spaces such as (Bathroom/s, WC, kitchen and washroom/s or shower room/s, and 
supplies fresh air into the main rooms (Living rooms, bedroom/s, office, …). 
The fresh and extracted airflows are separated and filtered. Only the energy from the extracted air is 
transferred to the new fresh air introduced. Thanks to IDEO 275 Ecowatt ’s high efficiency heat 
exchanger, performance can reach up to 95 %.
Condensation may occur at the moment of exchange, with the introduction of fresh air. This is 
recovered in a container for condensate, which should be connected to a waste water drain.

100 %

O 2

Thanks to its 100 % by-pass, the IDEO 275 Ecowatt enables you to cool your home in the summer.

2.2 Description of the IDEO-HR

Antenna

Filter access cover

D 160/150mm

Remote control module

User manual access cover

Содержание IDEO - 275 Ecowatt

Страница 1: ...CTB IDEO 275 Ecowatt Installation Manual...

Страница 2: ...Before manipulating this device disconnect the electricity supply During normal operation never stop the ventilation system...

Страница 3: ...homes Soler Palau will not be held liable for damage produced by Misuse Normal wear and tear of components Non observance of the instructions contained in this manual regarding safety use and start up...

Страница 4: ...ed airflows are separated and filtered Only the energy from the extracted air is transferred to the new fresh air introduced Thanks to IDEO 275 Ecowatt s high efficiency heat exchanger performance can...

Страница 5: ...avoid thermal losses and optimise the performance of the installation it is d d t i l t d t b f i th i recommended to use insulated tubes for moving the warm air Discharge extracted air to outside Th...

Страница 6: ...2 3 Dimensions Central unit Weight 51 Kg Remote controls Programmable module Kitchen boost...

Страница 7: ...Wall bracket 2 4 Placement On a vertical wall On the floor It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework...

Страница 8: ...fic kit option Support It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework necessary to insulate the condensate drain pipewo...

Страница 9: ...Y Kitchen Outlet roof caps CT 150 Toilets BDOP 125 BDOP 80 Toilets Air intake plenum PAP Air intake D150 Li i itti Or PAF 150 Circular Air intake wall hoods Living sitting room Bedrooms Or Or PAST Air...

Страница 10: ...TYPE DISTRIBUTION Outlet roof caps CT 150 Living sitting room BDOP 125 Kitchen BDOP 125 BDOP D80 RD80 Bedrooms Toilets BAR Toilets PAP Air intake D150mm BDOP D80 RD80 Or PAF 150 Circular Air intake D...

Страница 11: ...aracteristics of each installation If any component is missing or badly fitted normal operation may be impaired H05VV F 5G1 type cable Length 1 2 m Connection box Electrical panel Power supply Single...

Страница 12: ...type battery The programming module is located on the front of the machine This remote control can also be located on a wall The programming module is located on the front of the machine This remote c...

Страница 13: ...or large flow 6 By pass 7 Defrost mode 7 Defrost mode 8 Absence mode 9 Transmission reception level 10 Battery level 11 Default mode 12 Change filter 12 Change filter 13 Instant energy saving 14 Energ...

Страница 14: ...alidate with key 18 Validate with key 18 The pictogram with two fans will flash Validate with key 18 Adjust the maximum desired flow using keys 19 and 20 in 5 m3 h steps according to the configuration...

Страница 15: ...ass Select with key 18 Select ON using keys 19 or 20 Validate with key 18 You can disable the forced by pass mode at any time To do this Navigate with keys 19 or 20 to pictogram 6 showing the By pass...

Страница 16: ...played 11 This icon is displayed when one of the components is out of service motor probe This icon is displayed when one of the components is out of service motor probe sensor Or if the IDEO detects...