•  Transported air temperature depends on the applied climatic category (see the designation key).
•  The maximum permissible concentration of solids and dust in the handled air is 10 mg/m3.
•  The unit is rated as a Class I electrical appliance.
•  Ingress protection rating against access to hazardous parts and water ingress – IPX4.

The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.

L

B

Ø D

Ø D1
Ø D2

Ø d

n holes

MODEL

Dimensions [mm]

L

D

D1

D2

d/n

B

VDO-400

400

400

450

490

8/12

525

VDO-450

400, 500

450

500

540

8/12

580

VDO-500

400, 500, 550

500

560

600

12/12

620

VDO-560

400, 500, 550

560

620

660

12/12

680

VDO-630

400, 500, 600, 700

630

690

730

12/12

750

VDO-710

450, 560, 750

710

770

810

12/16

845

VDO-800

400, 500, 550, 600

800

860

900

12/16

925

VDO-900

400, 500, 600, 700

900

970

1015

15/16

1025

VDO-1000

550, 650, 750, 850

1000

1070

1115

15/16

1140

VDO-1120

550, 650, 750, 850

1120

1190

1270

15/20

1280

VDO-1250

550, 650, 750, 850

1250

1320

1400

15/20

1450

Label place

Technical specifications of the smoke extraction fan

TECHNICAL DATA

Содержание VPQ 710

Страница 1: ...VDO Axial smoke extraction fan USER S MANUAL...

Страница 2: ...The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this...

Страница 3: ...life of the unit While transferring the unit control the user s manual must be turned over to the receiving operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power...

Страница 4: ...nit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits s...

Страница 5: ...ficiency effectiveness and safety Used for continuous operation in a general ventilation system THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIE...

Страница 6: ...limate 60 40 C T tropical climate 10 50 C M maritime moderately cold climate 40 40 C O general climatic modification except maritime climate 60 50 C OM general maritime climatic modification 40 40 C V...

Страница 7: ...ribed in this manual L B D D1 D2 d n holes MODEL Dimensions mm L D D1 D2 d n B VDO 400 400 400 450 490 8 12 525 VDO 450 400 500 450 500 540 8 12 580 VDO 500 400 500 550 500 560 600 12 12 620 VDO 560 4...

Страница 8: ...casing for easy maintenance All the casing components are powder coated for improved protection against the environmental effects The fan impeller has a split design and is connected to the motors The...

Страница 9: ...be 3 4 D where D is the inner diameter of the fan The length of the straight duct section downstream of the fan should be 1 5 2 D Reduction of the recommended duct length values results in a drop of t...

Страница 10: ...tional to the square of velocity decrement The fan should not be equipped with a downstream contractor Installation near bends To install the fan directly downstream of a bend elbow use a curved secti...

Страница 11: ...automatic control system The fan motor is rated for connection to three phase AC 400 V 50 60 Hz Connect the fan motor via the terminal block according to the electrical mains wiring diagram using a d...

Страница 12: ...s equipped with a damping device to smooth out the inrush the high startup torque has no adverse effects on the operation of the driven mechanism Soft start SS starting A soft starter gradually increa...

Страница 13: ...tive equipment the higher the chances of success The use of an FC in this case helps solve the problem fundamentally Standard switching equipment automatic circuit breakers contactors and motor starte...

Страница 14: ...n will not start No power supply Check the mains switch Check the electrical connections against the wiring diagram Jammed motor Carefully check the fan impeller for possible seizure and eliminate it...

Страница 15: ...network Wrong choice of the fan Replace the fan with a unit of proper standard size The fan supplies less air than expected Wrong calculation of the ventilation network and wrong selection of the fan...

Страница 16: ...ssible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protec...

Страница 17: ...technical maintenance of the unit External damage to the unit casing excluding external modifications as required for installation and internal components caused by the user Redesign or engineering c...

Страница 18: ...18 VDO www ventilation system com...

Страница 19: ...IFICATE The VDO _______________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician...

Страница 20: ...V118 1EN 01...

Отзывы: