Vents VKS 200 Скачать руководство пользователя страница 8

8

VK

www.ventilation-system.com

1

2

3

4

5

Mounting sequence:

1. Remove the bolts on both sides of the casing, install the mounting brackets and tighten the bolts, aligning the holes in the brackets 
with the holes in the casing.
2. Mark holes for drilling.
3. Drill the holes in the wall or the ceiling for dowels.
4. Fix the fan with the screws.
5. Connect the air ducts of the corresponding diameter to the fan.

MOUNTING AND SET-UP

The fan is suitable both for horizontal or vertical mounting on the floor, on the wall or on the ceiling. Air motion in the system must 
be in compliance with the direction of the arrow on the fan casing. Install a hood on the intake spigot side in case of vertical fan 
installation. When installing the fan horizontally, provide a straight air duct section at least 1 m long on the intake spigot side.

9

1 m

READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

Temperature sensor failure

Alarm code

Alarm description

Two short pulses

Short circuit of the temperature sensor

One pulse

Breakdown of the temperature sensor

The motor shuts down

Содержание VKS 200

Страница 1: ...VK Centrifugal fan USER S MANUAL...

Страница 2: ...VK unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workpla...

Страница 3: ...operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations Unpack the unit with care The unit must be grounded While installi...

Страница 4: ...es in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct...

Страница 5: ...ogenic germs Name Number Fan 1 pc Screws and dowels 4 pc Mounting bracket 2 pc User s manual 1 pc Packing box 1 pc VK S 100 X Additional options Q low power motor Duo double speed motor U speed contro...

Страница 6: ...250 VK 315 VKS 315 Voltage V 50 Hz 1 230 Power W 107 173 108 173 200 310 Current A 0 47 0 76 0 47 0 76 0 88 1 36 Maximum air flow m3 h 780 930 865 1080 1340 1700 RPM min 1 2660 2125 2560 2090 2655 25...

Страница 7: ...speed as the room air temperature exceeds the set point As the air temperature drops 2 C below the set point or if the initial temperature is below the set point the TSI goes out and the fan operates...

Страница 8: ...n is suitable both for horizontal or vertical mounting on the floor on the wall or on the ceiling Air motion in the system must be in compliance with the direction of the arrow on the fan casing Insta...

Страница 9: ...in the event of overload or short circuit The position of the external automatic circuit breaker must ensure free access for quick power off of the unit The trip current of the automatic circuit break...

Страница 10: ...d only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm...

Страница 11: ...ler for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including s...

Страница 12: ...cceptance of the complete unit delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature INSTALLATION CERTIFICATE The VK __________ unit is installed pursua...

Страница 13: ...13 www ventilation system com...

Страница 14: ...14 VK www ventilation system com...

Страница 15: ...15 www ventilation system com...

Страница 16: ...V02EN 12...

Отзывы: