8
VK
www.ventilation-system.com
1
2
3
4
5
Mounting sequence:
1. Remove the bolts on both sides of the casing, install the mounting brackets and tighten the bolts, aligning the holes in the brackets
with the holes in the casing.
2. Mark holes for drilling.
3. Drill the holes in the wall or the ceiling for dowels.
4. Fix the fan with the screws.
5. Connect the air ducts of the corresponding diameter to the fan.
MOUNTING AND SET-UP
The fan is suitable both for horizontal or vertical mounting on the floor, on the wall or on the ceiling. Air motion in the system must
be in compliance with the direction of the arrow on the fan casing. Install a hood on the intake spigot side in case of vertical fan
installation. When installing the fan horizontally, provide a straight air duct section at least 1 m long on the intake spigot side.
9
1 m
READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.
Temperature sensor failure
Alarm code
Alarm description
Two short pulses
Short circuit of the temperature sensor
One pulse
Breakdown of the temperature sensor
The motor shuts down