background image

8

VKP/VKPI/VKPF/VKPFI

www.ventilation-system.com

VKPF/VKPFI

4E 400x200 4D 400x200 4E 500x250 4D 500x250 6E 500x250

Unit voltage [V/50 (60) Hz] 

1~ 230

3~ 400

1~ 230

3~ 400

1~ 230

Power [W] 

295

282

535

570

244

Current [A] 

1.32

0.60

2.49

0.94

1.22

Maximum air flow [m

3

/h] 

1440

1470

1750

1850

1460

RPM [min

-1

1350

1300

1250

1270

910

Sound pressure level at 3 m distance [dBA] 

50/42*

52/43*

53/44*

54/44*

45/37*

Transported air temperature [°С] 

-25...+40

-25...+45

-20...+40

-20...+40

-20...+50

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating

IP54

IP54

IP54

IP54

IP54

VKPF/VKPFI

6D 500x250 4E 500x300 4D 500x300 6E 500x300 6D 500x300

Unit voltage [V/50 (60) Hz] 

3~ 400

1~ 230

3~ 400

1~ 230

3~ 400

Power [W] 

274

710

855

283

303

Current [A] 

0.67

3.10

1.70

1.59

0.8

Maximum air flow [m

3

/h] 

1490

2350

2350

1550

1620

RPM [min

-1

930

1230

1300

890

910

Sound pressure level at 3 m distance [dBA] 

45/38*

57/47*

56/47*

47/39*

51/41*

Transported air temperature [°С] 

-20...+60

-25...+70

-20...+50

-20...+70

-20...+60

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating

IP54

IP54

IP54

IP54

IP54

VKPF/VKPFI

4E 600х300 4D 600х300 6E 600х300 6D 600х300 4E 600х350

Unit voltage [V/50 (60) Hz] 

1~ 230

3~ 400

1~ 230

3~ 400

1~ 230

Power [W] 

1240

1560

419

397

2840

Current [A] 

6.45

2.73

2.05

0.78

13.90

Maximum air flow [m

3

/h] 

2950

3740

2260

2320

4260

RPM [min

-1

1210

1310

870

920

1260

Sound pressure level at 3 m distance [dBA] 

59/51*

57/50*

50/42*

49/41*

59/51*

Transported air temperature [°С] 

-25...+50

-25...+65

-20...+70

-20...+70

-20...+40

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating

IP54

IP54

IP54

IP54

IP54

* Parameters for a VKPFI model.

Содержание VKPF

Страница 1: ...Duct rectangular fan USER S MANUAL VKP VKPI VKPF VKPFI...

Страница 2: ...ractical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of th...

Страница 3: ...ed Do not expose the device to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in...

Страница 4: ...ed it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a safety hazard Ensure that the appliance is switched off from the supply mains before rem...

Страница 5: ...PRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORISED ACCESS B...

Страница 6: ...X4 IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP44 IP44 IP44 IP44 IP54 IP54 IP54 IP54 VKP VKPI 4E 600 300 4D 600 300 4E 600 350 Voltage V 1 220 240 3 400 1 220 240 Frequency Hz 50 60 50 60 50 60 Pow...

Страница 7: ...0 735 36 38 VKP 4D 600 350 600 620 640 350 370 390 390 735 36 38 Model Dimensions mm Weight kg B B1 B2 H H1 H2 H3 L VKP 4D 1000 500 1000 1020 1040 500 520 540 720 1150 126 0 Model Dimensions mm Weight...

Страница 8: ...303 Current A 0 67 3 10 1 70 1 59 0 8 Maximum air flow m3 h 1490 2350 2350 1550 1620 RPM min 1 930 1230 1300 890 910 Sound pressure level at 3 m distance dBA 45 38 57 47 56 47 47 39 51 41 Transported...

Страница 9: ...25 40 Ingress protection rating of the unit IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP54 IP54 IP54 IP54 VKPF VKPFI 6D 700 400 4D 800 500 6D 800 500 8D 800 500 Unit voltage V 50 60 Hz 3 400 3 400...

Страница 10: ...300 320 340 375 680 35 VKPF 4D 600 300 600 620 640 300 320 340 375 680 35 VKPF 6E 600 300 600 620 640 300 320 340 375 680 35 VKPF 6D 600 300 600 620 640 300 320 340 375 680 35 VKPF 4E 600 350 600 620...

Страница 11: ...0 300 600 620 640 670 300 320 340 480 680 56 VKPFI 4D 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6E 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6D 600 300 600 620 640 670 300 320 34...

Страница 12: ...hat the arrow on the fan casing matches the air flow direction in the system The fan should always be installed on its own hangers so that it does not load the flexible connectors and the connected ai...

Страница 13: ...ference only The actual conductor cross section selection must be based on its type the maximum permissible heating insulation length and installation method in the air pipes or inside walls The recom...

Страница 14: ...n VKP VKPI 4D 600 300 units with a three phase motor Wiring diagram for VKP VKPI 4D 600 350 units with a three phase motor 400 V 50 60 Hz L N X1 1 2 3 N L QF PE 230 50 60 4 PE L2 L1 QF PE 400 50 60 L2...

Страница 15: ...y set The TW1 TW2 TK1 TK2 are the electrical leads of the normally closed contact of the motor overheating protection Connect the contact in series to power circuit of the magnetic starter coil KM1 th...

Страница 16: ...or current regulate the torque Regulation by limiting the current sets the maximum in rush current equal to 300 400 or 250 in some rare instances of the rated current and reduces torque characteristic...

Страница 17: ...or protection system less sensitive As a result the switching equipment will not be able to detect motor overload in time due to a high current sensing threshold Such problems as mentioned above can o...

Страница 18: ...18 VKP VKPI VKPF VKPFI www ventilation system com 1 3 4 5 6 2...

Страница 19: ...andling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechani...

Страница 20: ...ct the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual i...

Страница 21: ...STALLATION CERTIFICATE The VKP _____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Страница 22: ...22 VKP VKPI VKPF VKPFI www ventilation system com...

Страница 23: ...23 www ventilation system com VKP VKPI VKPF VKPFI...

Страница 24: ...V07EN 04...

Отзывы: