Vents VKPF Скачать руководство пользователя страница 3

3

www.ventilation-system.com

VKP/VKPI/VKPF/VKPFI

SAFETY REQUIREMENTS

All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing and 
operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are allowed 

for installation and maintenance. The present user’s manual should be carefully read before 

beginning works.

•  Check the unit for any visible damage of the impeller, the casing, and the grille before starting 

installation. The casing internals must be free of any foreign objects that can damage the impeller 
blades. 

•  While mounting the unit, avoid compression of the casing! Deformation of the casing may result 

in motor jam and excessive noise.

•  Misuse of the unit and any unauthorised modifications are not allowed.
•  Do not expose the device to adverse atmospheric agents (rain, sun, etc.).
•  Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 

materials.

•  Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, 

insecticides, etc.

•  Do not close or block the intake or extract vents in order to ensure the efficient air flow.
•  Do not sit on the unit and do not put objects on it.
•  The information in this user’s manual was correct at the time of the document’s preparation. 
•  The Company reserves the right to modify the technical characteristics, design, or configuration 

of its products at any time in order to incorporate the latest technological developments.

WARNING! Similar to the use of any other household electrical appliances when operating 

this fan, the following basic rules must be followed:

•  Never touch the unit with wet or damp hands.
•  Never touch the unit when barefoot.

The installation site of the fan must have protective elements that prevent foreign objects from 
entering the fan.
When starting, setting up and operating the fan, the exhaust and supply spigots must be protected 
to prevent injury from the rotating parts of the fan.

Содержание VKPF

Страница 1: ...Duct rectangular fan USER S MANUAL VKP VKPI VKPF VKPFI...

Страница 2: ...ractical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of th...

Страница 3: ...ed Do not expose the device to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in...

Страница 4: ...ed it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a safety hazard Ensure that the appliance is switched off from the supply mains before rem...

Страница 5: ...PRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORISED ACCESS B...

Страница 6: ...X4 IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP44 IP44 IP44 IP44 IP54 IP54 IP54 IP54 VKP VKPI 4E 600 300 4D 600 300 4E 600 350 Voltage V 1 220 240 3 400 1 220 240 Frequency Hz 50 60 50 60 50 60 Pow...

Страница 7: ...0 735 36 38 VKP 4D 600 350 600 620 640 350 370 390 390 735 36 38 Model Dimensions mm Weight kg B B1 B2 H H1 H2 H3 L VKP 4D 1000 500 1000 1020 1040 500 520 540 720 1150 126 0 Model Dimensions mm Weight...

Страница 8: ...303 Current A 0 67 3 10 1 70 1 59 0 8 Maximum air flow m3 h 1490 2350 2350 1550 1620 RPM min 1 930 1230 1300 890 910 Sound pressure level at 3 m distance dBA 45 38 57 47 56 47 47 39 51 41 Transported...

Страница 9: ...25 40 Ingress protection rating of the unit IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP54 IP54 IP54 IP54 VKPF VKPFI 6D 700 400 4D 800 500 6D 800 500 8D 800 500 Unit voltage V 50 60 Hz 3 400 3 400...

Страница 10: ...300 320 340 375 680 35 VKPF 4D 600 300 600 620 640 300 320 340 375 680 35 VKPF 6E 600 300 600 620 640 300 320 340 375 680 35 VKPF 6D 600 300 600 620 640 300 320 340 375 680 35 VKPF 4E 600 350 600 620...

Страница 11: ...0 300 600 620 640 670 300 320 340 480 680 56 VKPFI 4D 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6E 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6D 600 300 600 620 640 670 300 320 34...

Страница 12: ...hat the arrow on the fan casing matches the air flow direction in the system The fan should always be installed on its own hangers so that it does not load the flexible connectors and the connected ai...

Страница 13: ...ference only The actual conductor cross section selection must be based on its type the maximum permissible heating insulation length and installation method in the air pipes or inside walls The recom...

Страница 14: ...n VKP VKPI 4D 600 300 units with a three phase motor Wiring diagram for VKP VKPI 4D 600 350 units with a three phase motor 400 V 50 60 Hz L N X1 1 2 3 N L QF PE 230 50 60 4 PE L2 L1 QF PE 400 50 60 L2...

Страница 15: ...y set The TW1 TW2 TK1 TK2 are the electrical leads of the normally closed contact of the motor overheating protection Connect the contact in series to power circuit of the magnetic starter coil KM1 th...

Страница 16: ...or current regulate the torque Regulation by limiting the current sets the maximum in rush current equal to 300 400 or 250 in some rare instances of the rated current and reduces torque characteristic...

Страница 17: ...or protection system less sensitive As a result the switching equipment will not be able to detect motor overload in time due to a high current sensing threshold Such problems as mentioned above can o...

Страница 18: ...18 VKP VKPI VKPF VKPFI www ventilation system com 1 3 4 5 6 2...

Страница 19: ...andling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechani...

Страница 20: ...ct the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual i...

Страница 21: ...STALLATION CERTIFICATE The VKP _____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Страница 22: ...22 VKP VKPI VKPF VKPFI www ventilation system com...

Страница 23: ...23 www ventilation system com VKP VKPI VKPF VKPFI...

Страница 24: ...V07EN 04...

Отзывы: