8
Micra 150 E
CONNECTION TO pOwER MAINS
DISCONNECT THE UNIT fROM THE pOwER MAINS pRIOR TO ANY OpERATIONS.
THE UNIT MUST bE pLUggED INTO A pROpERLY INSTALLED pOwER SOCKET
wITH AN EARTHED TERMINAL.
THE RATED ELECTRICAL pARAMETERS Of THE UNIT ARE SHOwN ON THE
RATINg pLATE.
ANY TAMpERINg wITH THE INTERNAL CONNECTIONS IS pROHIbITED AND
wILL VOID THE wARRANTY.
The unit is designed for connection to 230 V / 50 Hz single-phase AC mains.
The unit is supplied with a power cable and a plug. The unit must be connected to power mains through a grounded power socket
compliant with IEC 60884-1. The power cable is pre-wired to the terminal block X1 by the manufacturer, fig. 7.
Connect the unit to power mains through the external automatic circuit breaker integrated into the fixed wiring system. Install the
circuit breaker to have a free quick access in case of need to turn the unit off promptly.
The circuit breaker trip current must be in compliance with the current consumption. The recommended circuit breaker rated current
is 2.5 A. While selecting the automatic circuit breaker consider the maximum wire temperature that depends on the wire type, insulation,
length and layout way (open wire mounting, channel type or wall-mounted).
Fig. 7. Power cable connection to terminal block
UNIT
1
L
L
N
PE
XP3
X1
N
PE
LA
2
3
4
5
6
~ 230 V / 50 Hz
UNIT CONTROL
Fig. 8. Control panel and remote controller
Unit on/off
Mode control buttons
(see description below)
Fan speed control buttons
Remote controller
Remote Controller
Unit on/off
Fan speed up
Heater on
Heater off
Fan speed down
Low speed on
High speed on
Medium speed on
Scheduled
operation on
Timer on/off
Control panel