background image

3

vents-us.com

•  Do not change the power cable length 

at your own discretion. Do not bend the 
power cable. Avoid damaging the power 
cable. Do not put any foreign objects on the 
power cable.

•  Do not lay the power cable of the unit in 

close proximity to heating equipment.

•  Do not use damaged equipment or cables 

when connecting the unit to power mains.

•  Do not operate the unit outside the 

temperature range stated in the user’s 
manual. Do not operate the unit in 
aggressive or explosive environments.

•  Do not touch the unit controls with wet 

hands. Do not carry out the installation and 
maintenance operations with wet hands.

•  Do not wash the unit with water. Protect 

the electric parts of the unit against ingress 
of water. 

•  Do not allow children to operate the unit.

•  Disconnect the unit from power mains prior 

to any technical  maintenance.

•  Do not store any explosive or highly 

flammable substances in close proximity to 
the unit.

•  When the unit generates unusual sounds, 

odour, or emits smoke, disconnect it from 
power supply and contact the Seller.

•  Do not open the unit during operation.

•  Do not direct the air flow produced by the 

unit towards open flame or ignition sources.

•  Do not block the air duct when the unit is 

switched on.

•  In case of continuous operation of the unit, 

periodically check the security of mounting.

•  Do not sit on the unit and avoid placing 

foreign objects on it.

•  Use the unit only for its intended purpose.

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE.

Содержание CBF 110

Страница 1: ...CBF 110 130 CBF 110 130 T TH TP CBF 110 130 LIGHT CBF 110 130 LIGHT T TH TP Centrifugal ceiling fan USER S MANUAL...

Страница 2: ...or to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must...

Страница 3: ...ic parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly fla...

Страница 4: ...s THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY P...

Страница 5: ...ing bracket 4 pcs Fastening kit 1 pc User s manual 1 pc Packing box 1 pc Ceileo 130 Light TP Additional options T timer TH humidity sensor and timer TP motion sensor and timer Basic options _ no integ...

Страница 6: ...8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 11 16 Ceileo 110 130 Light Ceileo 110 130 Light T TH TP 5 7 8 3 7 8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 2 7 6 8 3 16 4 13 16 The unit is desi...

Страница 7: ...73 SFP W l s 0 55 0 50 0 49 0 54 Weight kg 5 3 6 4 5 3 6 4 lbs 11 7 14 1 11 7 14 1 IP X4 SEC class D C For fans with light only TECHNICAL DATA CBF 110 130 DC T TH TP CBF 110 130 DC LIGHT T TH TP DESI...

Страница 8: ...f the fan is turned on or goes to high speed after countdown of a set turn on delay time adjustable from 0 to 3 minutes After the fan is turned off it keeps running for a set turn off delay time adjus...

Страница 9: ...E THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and loc...

Страница 10: ...dels with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor TH or TP via the opening in the grille and connect the sensor soc...

Страница 11: ...of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for mounting pur...

Страница 12: ...ERMINAL BOX FOR WIRING THE FAN L2 L1 N L N LT N L N L 1 2 3 4 5 6 7 LIGHT contact socket is available only for the models with LED light FAN 1 QF QF 120 V 60 Hz 120 V 60 Hz Remove the decorative grill...

Страница 13: ...to navigate in the Setup menu Press to select a current entry in the Setup menu After that the indicator displays the selected parameter value e g turn off delay timer setting Use or to change the va...

Страница 14: ...take the following values for the fan with an AC motor the fan is turned off the fan operates at reduced performance the fan operates at maximum performance Example 1 with these activated settings th...

Страница 15: ...SIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker Motor jam Turn the fan off Troubleshoot cloggi...

Страница 16: ...machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the origina...

Страница 17: ...recommended installation instructions Labor to remove and replace products is not covered The duration of any implied warranty is limited to the time period specified for the express warranty Some st...

Страница 18: ...equirements stated in the present user s manual Installation Company Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in ac...

Страница 19: ...19 vents us com...

Страница 20: ...VUSA166 1EN 01...

Отзывы: