background image

2

CBF

vents-us.com

CONTENTS

This user’s manual is the primary operating document intended for technical, maintenance and operations staff. 
The user’s manual contains information regarding the field of application, delivery package, operating principle, and design of the centrifugal 
fan CBF fan and all its modifications.  
Technical and maintenance staff must have proper theoretical knowledge and practical training specific to ventilation systems as well as the 
necessary skills to carry out the work in accordance with labour safety and construction regulations and standards applicable in the respective 
territory. 
The information provided in the present document is true as at the document preparation. 
Due to the continuous product development the company reserves the right to update the technical specifications, design or delivery 
package of its products. 
No part of the present publication may be reproduced, uploaded or saved in reference-providing information systems or translated into other 
languages in any form whatsoever without the company’s prior written consent.

SAFETY REQUIREMENTS

•  Please read the user’s manual carefully prior to installing and operating the unit.
•  All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical 

norms and standards must be observed when installing and operating the unit.

•  The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
•  Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
•  After a careful reading of the manual, keep it for the entire service life of the unit.
•  While transferring the unit control, the user’s manual must be turned over to the receiving operator.

UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS

•  Disconnect the unit from power mains prior 

to any installation operations.

•  Unpack the unit with care.

•  The unit must be grounded!

•  While installing the unit, follow the safety 

regulations specific to the use of electric 
tools.

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery Set ....................................................................................................................................................................................... 5
Designation key  ............................................................................................................................................................................ 5
Technical data .................................................................................................................................................................................. 6
Design and operating principle ........................................................................................................................................... 7
Mounting and set-up  ................................................................................................................................................................ 9
Connection to power mains  ................................................................................................................................................. 12
Maintenance .................................................................................................................................................................................... 14
Storage and transportation regulations  ........................................................................................................................ 16
Manufacturer’s Warranty ........................................................................................................................................................... 17
Acceptance certificate  .............................................................................................................................................................. 17
Seller information  ......................................................................................................................................................................... 18
Installation certificate .................................................................................................................................................................. 18
Warranty card ................................................................................................................................................................................... 18

READ AND SAVE THESE INSTRUCTIONS

Содержание CBF 110

Страница 1: ...CBF 110 130 CBF 110 130 T TH TP CBF 110 130 LIGHT CBF 110 130 LIGHT T TH TP Centrifugal ceiling fan USER S MANUAL...

Страница 2: ...or to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must...

Страница 3: ...ic parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly fla...

Страница 4: ...s THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY P...

Страница 5: ...ing bracket 4 pcs Fastening kit 1 pc User s manual 1 pc Packing box 1 pc Ceileo 130 Light TP Additional options T timer TH humidity sensor and timer TP motion sensor and timer Basic options _ no integ...

Страница 6: ...8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 11 16 Ceileo 110 130 Light Ceileo 110 130 Light T TH TP 5 7 8 3 7 8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 2 7 6 8 3 16 4 13 16 The unit is desi...

Страница 7: ...73 SFP W l s 0 55 0 50 0 49 0 54 Weight kg 5 3 6 4 5 3 6 4 lbs 11 7 14 1 11 7 14 1 IP X4 SEC class D C For fans with light only TECHNICAL DATA CBF 110 130 DC T TH TP CBF 110 130 DC LIGHT T TH TP DESI...

Страница 8: ...f the fan is turned on or goes to high speed after countdown of a set turn on delay time adjustable from 0 to 3 minutes After the fan is turned off it keeps running for a set turn off delay time adjus...

Страница 9: ...E THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and loc...

Страница 10: ...dels with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor TH or TP via the opening in the grille and connect the sensor soc...

Страница 11: ...of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for mounting pur...

Страница 12: ...ERMINAL BOX FOR WIRING THE FAN L2 L1 N L N LT N L N L 1 2 3 4 5 6 7 LIGHT contact socket is available only for the models with LED light FAN 1 QF QF 120 V 60 Hz 120 V 60 Hz Remove the decorative grill...

Страница 13: ...to navigate in the Setup menu Press to select a current entry in the Setup menu After that the indicator displays the selected parameter value e g turn off delay timer setting Use or to change the va...

Страница 14: ...take the following values for the fan with an AC motor the fan is turned off the fan operates at reduced performance the fan operates at maximum performance Example 1 with these activated settings th...

Страница 15: ...SIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker Motor jam Turn the fan off Troubleshoot cloggi...

Страница 16: ...machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the origina...

Страница 17: ...recommended installation instructions Labor to remove and replace products is not covered The duration of any implied warranty is limited to the time period specified for the express warranty Some st...

Страница 18: ...equirements stated in the present user s manual Installation Company Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in ac...

Страница 19: ...19 vents us com...

Страница 20: ...VUSA166 1EN 01...

Отзывы: