Page 32
Installation and Operation Manual - HES 240
ENGLISH
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
14
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
9" (229 mm)
9" (229 mm)
D
12 ¼" (311 mm)
12 ¼" (311 mm)
B
19" (483 mm)
19" (483 mm)
E
28 ¼ (718 mm)
28 ¼ (718 mm)
K
48" (122 cm)
48" (122 cm)
L
77" (196 cm)
77" (196 cm)
8.1.5 Mobile Home
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
14 ¼" (362 mm)
14 ¼" (362 mm)
B
18" (457 mm)
18" (457 mm)
E
27 ¼" (692 mm)
27 ¼" (692 mm)
C
11" (279 mm)
11" (279 mm)
F
20 ½" (521 mm)
20 ½" (521 mm)
8.1.6 Mobile Home With Heat Shield AC02710 or AC02762
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ¼" (159 mm)
6 ¼" (159 mm)
B
6" (152 mm)
6" (152 mm)
E
15 ¼" (387 mm)
15 ¼" (387 mm)
C
3" (76 mm)
3" (76 mm)
F
12 ½" (318 mm)
12 ½" (318 mm)
14
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.