background image

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when fl aming food   
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or fi lter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e.  Keep fan, fi lters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the fl ames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2.  The fi re is small and contained in the area where it started.
3.  The fi re department is being called.
4.  You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. 

Including fi re-rated construction.

b.  Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  NEVER place a switch where it can be reached from a tub or shower.
f.  Make sure the power is off before installing, wiring or maintenancing.

Содержание RH00830AS

Страница 1: ...Use Care and Installation Guide Model number Serial Number READ AND SAVE THESE INSTRUCTIONS RH00830AS RH00836AS AUG12 0101 ...

Страница 2: ......

Страница 3: ... Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Electronic Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Light Bulbs 13 TROUBLESHOOTING 14 WIRING DIAGRAMS 15 LIST OF PARTS AND ACCESSORIES 16 Table of Contents ...

Страница 4: ... of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT US...

Страница 5: ... electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a...

Страница 6: ...es Extension duct cover accessory RHEX008S Recirculating kit accessory RHRK008S HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS RH00830AS RH00836AS 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 Hardware package 1 6 round backdraft damper pre installed 2 50W GU 10 halogen light bulbs 2 Aluminum mesh filters ...

Страница 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Страница 8: ...e performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 16 for part number and ordering information D DAMAGE SHIPMENT INSTALLATION Please fully inspect unit for damage ...

Страница 9: ...de unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper ...

Страница 10: ...ood Specifi cation 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 53 RHEX008S EXTENSION min ducted 42 min recirc 46 max 80 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16 5 TOP SIDE FRONT ...

Страница 11: ...ort FIG A 2 9 Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using 2 M6 x 1 screws FIG A 3 10 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 11 Power up hood to verify all functions and check for leaks around duct tape 12 Place telescopic duct covers onto hood and extend inner top...

Страница 12: ...usted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brackets and air diverter plate Hood Models Part No Filters Brackets in pkg RH008 RHRK008S 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG C Run 6 ducting from top of hood and secure to air div...

Страница 13: ... Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Bright Dim and Off 4 Delay Off Timer Press to enable delay off timer blower will shut down after 5 minutes Features Controls Electronic Controls ...

Страница 14: ...cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergent...

Страница 15: ... by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup or use a rubber latex glove grip and turn the bulb counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn to page 16...

Страница 16: ...roperly after the thermally protected system cool down 5 Damaged capacitor 5 Change the capacitor 6 The switch board or control board is defective 6 Change defective part The unit is vibrating 1 The blower is not secured in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood The blower is working bu...

Страница 17: ...15 Wiring Diagrams ...

Страница 18: ...PART Replacement Parts Light Bulb GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit RHRK008S Replacement Charcoal Filters each RHCF001 Extension Duct Cover RHEK008S Order replacement parts from us by calling 1 888 750 1698 ...

Страница 19: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...