10
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard
Aluminum Mesh Filter set. Order according to its part number below. The standard Aluminum Mesh Filters are
intended to capture residue from cooking and the optional charcoal fi lters help to purify fumes exhausted from
cooking for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal fi lters, charcoal fi lter brackets and air diverter plate.
Hood Models
Part No.
Filters & Brackets in pkg.
RH008
RHRK008S
2
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run
6” ducting from top of hood and secure to air diverter plate.
3. Remove aluminum mesh fi lters from hood. Install charcoal fi lter
brackets inside fi lter opening. Note: screws to secure charcoal fi lter
brackets are already pre-installed in the hood and must fi rst be
removed. Clip charcoal fi lters onto charcoal fi lter brackets. (FIG. C)
4. Re-Install aluminum mesh fi lters.
For more details refer to manual
included with recirculating kit.
5. Charcoal fi lters must be replaced after every 120 hours of use (or
approximately every 3 to 4 months based on an average of 1 - 2 hrs. of
daily cooking time).
Charcoal Filter Replacements
Hood Model
Part No.
Qty to Order
RH008
RHCF001
2
DO NOT WASH CHARCOAL FILTERS. Charcoal fi lters may need
to be changed more often depending on cooking habits.
Installation –
Ductless Recirculating
FIG. C
Содержание RH00830AS
Страница 2: ......
Страница 17: ...15 Wiring Diagrams ...