5.0 Routine Testing and Maintenance.
It is essential that the Meditell 2 system is regularly tested and maintained properly to ensure consistent and
reliable operation.
5.1 Routine Testing
It is important that the entire Meditell 2 system is regularly tested.
Once per month each “Standard Call ” device and “Priority Call” Device should be activated to ensure correct
operation.
It is good practise to test the “Reset” devices regularly to allow easy system resetting when required.
The ECU Front mounted “Reset / Mute” button can be used to perform a simple self test of the system
warning devices. See Section 3.5 for details.
The times mentioned above should be considered as minimum test periods, more frequent tests are
preferable.
5.2 Routine Battery Maintenance
If the system has a battery back up unit installed, It is important to regularly test it.
Every 6 months
the mains power should be turned off and a “Call Alarm” activation generated, the system
“Warning Devices” should sound and illuminate at similar sound and light level as when then the system is
operating from the mains supply.
The back up batteries should be replaced every 4 years.