Step A/ Connect the EARTH wire to the terminal port marked “     ”on the terminal block
 mounting bracket (Fig. 8a). 
Step B/ Connect the supply LIVE wire to the wall controller terminal port labelled 
"TO 240V/50Hz". (Fig. 8b). 
Step C/ Connect a wire from the Fan Live "L" from the terminal block mounting bracket 
(Fig. 8a), to the terminal port labelled "FOR FAN-L" on the wall controller (Fig. 8b). 
Step D/ Connect a wire from the Light Live

“  ”

 from the terminal mounting bracket (Fig. 8a), 

to the terminal port labelled "FOR LIGHT-L" on the wall controller (Fig. 8b).
 

Note

: The fan light wiring is only applicable to fan models with a light kit. 

Step F/ Connect the supply Neutral wire to the terminal port marked "N" on the terminal block 
mounting bracket (Fig. 8a).
Once all the above steps have been followed, you are now ready to restore the mains power 
supply. Make sure there is nobody near or under the fan, then turn ON the fan (and light switch 
if included in your model) to test. 

If you notice any problems, please recheck the installation and wiring procedures above, as 
well as the "Troubleshooting Checklist' on page11. 

8

     

The wall control shall fit into existing gang block or wall plate. If you do not flush mount 

         the control, use a standard single gang mounting block; 
     

Careful not to mix the supply live and the fan live connection. Reverse connection of 

         the speed control will affect the correct operation of the fan; 
     

After the wiring connections are completed, ensure that all wires are arranged in a tidy 

         manner, and make sure the ball sits well into the bracket, as it is important to reduce your
         fan from wobbling. 

8. REVERSING SWITCH

Switch shall be in the 

summer” position to make the fan rotate in the anticlockwise direction 

during summer season, and in the 

winter” position to make the fan rotate clockwise direction 

during winter season.

Warning

: For your safety, before changing between 

winter” or 

summer” position, make 

sure the fan is switched OFF and the fan blades have come to a complete stop.

Warmer Weather 

– 

Have the airflow directed downwards.

Cooler Weather 

– 

Have the airflow directed upwards.

  

SUMMER

WINTER

DOWNDRAFT

UPDRAFT

Clockwise Rotation

Counter Clockwise rotation

Summer

:

Air

 

is

 

Blown downwards

,

producing

 

cool breeze

Winter

:

Warm

 

air

 

naturally

 

rises

towards

 

the

 

ceiling. The upward 

airflow pushes this warm air away
from the ceiling, circulating it 
within the room

Содержание Z483EXTSS

Страница 1: ...ALLATION AND FAN OPERATION INSTALLATION OPERATION MAINTENANCE This photo is for reference only it doesn t mean you are purchasing identical products Fan picture is for illustration purpose only styles may vary according to the particular models Model No Z524EXTSS Z564EXTSS Z483EXTSS ...

Страница 2: ...must be able to support the weight of 6 times that of the net weight of the fan Net weights can be found on the bottom of the unit box If you are mounting the fan to a ceiling junction box the box and fixing must be able to support the moving weight of the fan and must not twist or work loose 5 The fan must be earthed 6 Do not connect the fan motor to a dimmer switch This may give an unsatisfactor...

Страница 3: ...g children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance The important safeguards and instructions appearing in this manual are not meant to c...

Страница 4: ... 16 13 14 12 7 6 Mounting Bracket Terminal Block Hanger Ball Upper Canopy Screws Fixing Canopy And Mounting Bracket Screws Fixing Mounting Bracket And Ceiling Downrod Screw Fixing Lower Canopy And Downrod Lower Canopy Screws Fixing Blade To Motor Reverse Switch Screws And Nuts Fixing Downrod To The Switch Bracket Blade Switch Bracket Motor Decorative Knob Mounting Plate Hanging System 1 Ceiling Jo...

Страница 5: ...ot covered by warranty Choose a location for mounting the fan where the blade will have at least 2 1m of clearance from all objects If the location you have chosen does not have a suitable support beam install a 2 x 4 brace between the ceiling joists as a support medium The brace between the ceiling joists must be strong enough to support a 30 35kg weight 2 M O U N T I N G T H E B R A C K E T Secu...

Страница 6: ...efer to point 8 WIRING INSTRUCTION MOUNTING BRACKET WALL CONTROL 5 For Quick Fix Series after wiring The connection you can put the keyhole on the upper canopy over the screws on the mounting bracket Then turn clock wise and tighten screws Screw the decorative nut into the end of the motor shaft If your ceiling fan has no light kit then skip point 7 Refer to point 8 for electrical wiring instructi...

Страница 7: ...t kit supply wires B Insert the light kit supply wires through the adaptor ensuring that the star washer is to the back of the light kit plate and screw the adaptor into the fan motor shaft and secure C Secure the light kit onto the fan via the adaptor and then connect the wiring to the terminal block located on the plate of the Light Kit WARNING MAKE SURE ACTIVE TO L AND NEUTRAL TO N OF THE LUMIN...

Страница 8: ...wn FOR FAN L Brown Light Switch ACTIVE Wiring diagram 8b Warning For your safety ensure the mains supply is switched OFF to the wiring circuit before performing any electrical wiring tasks Follow the installation instruction below to complete the electrical wiring to the ceiling fan and wall controller Installation tips All pole disconnection switch must be included in the fixed wiring Only use th...

Страница 9: ... on page11 8 The wall control shall fit into existing gang block or wall plate If you do not flush mount the control use a standard single gang mounting block Careful not to mix the supply live and the fan live connection Reverse connection of the speed control will affect the correct operation of the fan After the wiring connections are completed ensure that all wires are arranged in a tidy manne...

Страница 10: ...equired C Blade tracking may be checked simply by use of a household yardstick as shown in below Figure Place the yardstick vertically against the ceiling and even with the outside leading edge of a blade Note the distance of the edge of a blade same as others Turn the blade slowly by hand to check the remaining blades If a blade is out of alignment the blade holder may be gently bent up or down t...

Страница 11: ... Use a soft cloth soaked with WD 40 or equivalent neutral oil and wipe over fan completely 2 Ensure the neutral oil covers all surfaces and reaches to all the joint areas 3 After treatment dry the fan with a soft cloth Periodic cleaning of your fan will need to be carried out as being an outdoor fan these are susceptible to tea staining and rusting due to moisture build up If tea staining or rusti...

Страница 12: ...ise A Fan blades are not horizontal to ceiling B Blade screws are loose A Top canopy touching ceiling B Loose fan blade screws C Ceiling fan not secured against ceiling D Incorrect speed controller A Allow for at least for 8 hours settling in period A Measure the clearance between ceiling and blades make sure the figures are the same otherwire small adjustments on blade holders will be required B ...

Страница 13: ...ntair c Repair of defects caused by accident fire misuse alterations modification negligence incorrect or incomplete installation operation any unauthorized person attempting to repair the ceiling fan or acts of God will not be covered d Claims or damage to furniture carpet wall ceiling foundations or any other consequential loss either direct or indirectly resulting from a faulty ceiling fan 7 Ex...

Страница 14: ...nd place of purchase and installing electricians details including Electrical Licence Number Service cannot be arranged without this information Prior to requesting service please consult the Trouble shooting check list All electric motors including fans make some noise and may feel hot to touch this is not a Fault Some fans wobble more than others even the same model Blades are weighed to matchin...

Страница 15: ...WARRANTY DETAIL Retain this for your personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER DATE OF PURCHASE SERIAL NUMBER INSTALLING LICENSED ELECTRICAN LICENCE No ATTACH PROOF OF PURCHASE HERE ...

Отзывы: