background image

INSTALLATION

WALL INSTALLATION

CEILING INSTALLATION

WARNING: 

For your safety, all electrical work must be carried out by a licensed electrician.

WARNING: 

Ensure the power supply to the exhaust fan is switched OFF before carrying out  

 

any installation and maintenance.

NOTE:

  

A double pole disconnection mechanism must be incorporated in the fixed wiring  

 

of the exhaust fan.

1. 

Find a suitable location and cut the appropriate size hole for the unit. Ensure there are  

 

no cables or pipes behind the wall when cutting. The hole should slope slightly to the  

 

external wall, this will allow drainage of any ingress from rain.

2.  Remove the front panel of the exhaust fan and position against the wall, and mark the  
 

four fixing screw points and cable entry, and then drill to suit.

3.  Place the exhaust fan through the cut out hole and position in place.
4.  Connect the Live and Neutral supply wiring to the terminal block, replace the terminal  
 

block cover and secure with screws.

5.  Secure the fan to the wall via the four screws and mounting holes.
6.  Replace the front panel and external shutter (External shutter not supplied).

1. 

Find a suitable location and cut the appropriate size diameter. Ensure there are no    

 

cables or pipes above the ceiling when cutting.

2.  Remove the front panel of the exhaust fan and position against the ceiling mounting   
 

surface and mark the four fixing screw points and cable entry, then drill to suit.

3.   Place the exhaust fan through the cut out hole and position the exhaust fan in place.
4.  Connect the Live and Neutral supply wiring to the terminal block, replace the terminal  
 

block cover and secure with screws.

5.  Secure the fan to the wall via the four screws and mounting holes.
6.  Replace the front panel.

NOTE:

 

Where ducting (not included) is used, ensure the outlet ducted is such that to   

 

avoid the back-flow of gases into the room from the open flue of gas or other   

 

fuel burning appliances.

Содержание PRO-V Slimline VSLF100

Страница 1: ...INSTALLATION AND WIRING INSTRUCTIONS Slimline Exhaust Fans MODEL VSLF100 VSLF125 VSLF150 READ THE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING ...

Страница 2: ...led at least 120cm above any hotplate and must have at least 50cm clearance at the rear of the blades Minimum installation height is 2 1metres from the floor to the bottom of the exhaust fan If the room where the fan is to be installed already contains a stove water heater or a gas fire it is essential to ensure that the air supply to the room is enough for both the fan and the combustion applianc...

Страница 3: ...throoms nearby sinks and water taps 2 For the exhaust fan to work efficiently replacement of air volume equivalent to what is being extracted must be able to enter the room In general this air would be drawn under the door or through a slightly opened window If the room is air tight the fan will function poorly Supply cable entry Terminal block Fig 3 ...

Страница 4: ...e Live and Neutral supply wiring to the terminal block replace the terminal block cover and secure with screws 5 Secure the fan to the wall via the four screws and mounting holes 6 Replace the front panel and external shutter External shutter not supplied 1 Find a suitable location and cut the appropriate size diameter Ensure there are no cables or pipes above the ceiling when cutting 2 Remove the...

Страница 5: ...ut any maintenance ensure the power is switched OFF from the mains power supply 1 Wipe down the fascia and grilles with a wet soapy cloth only Do not allow water to have contact with the electrical parts such as the motor 2 Never use petrol benzene thinner or any other chemicals for cleaning the ventilation fan 3 Do not immerse resin parts into hot water over 60 C 4 Do not place hot objects near o...

Отзывы: