IMPORTANT INFORMATION

PARTS IDENTIFICATION

DIMENSIONS

WARNING: FOR YOUR SAFETY, ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A 

LICENSED ELECTRICIAN.

This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instructions on the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance. 

Fan must be installed at least 120cm above any hotplate, and must have at least 50cm 
clearance at the rear of the blades.

Minimum installation height is 2.1metres from the floor to the bottom of the exhaust fan.

If the room where the fan is to be installed already contains a stove, water heater or a gas 
fire, it is essential to ensure that the air supply to the room is enough for both the fan and the 
combustion appliance.

Please check that the appliance has not been damaged in transit before installation.

Ensure the electrical specifications label corresponds to your electrical supply correctly. 

MODEL

A

B

C

D

Cut-Out 

Hole Size

VSLF100

158 x 158mm

21

58

98

Ø98mm

VSLF125

180 x 180mm

21

71

116

Ø116mm

VSLF150

209 x 209mm

21

82

148

Ø148mm

Содержание PRO-V Slimline VSLF100

Страница 1: ...INSTALLATION AND WIRING INSTRUCTIONS Slimline Exhaust Fans MODEL VSLF100 VSLF125 VSLF150 READ THE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING ...

Страница 2: ...led at least 120cm above any hotplate and must have at least 50cm clearance at the rear of the blades Minimum installation height is 2 1metres from the floor to the bottom of the exhaust fan If the room where the fan is to be installed already contains a stove water heater or a gas fire it is essential to ensure that the air supply to the room is enough for both the fan and the combustion applianc...

Страница 3: ...throoms nearby sinks and water taps 2 For the exhaust fan to work efficiently replacement of air volume equivalent to what is being extracted must be able to enter the room In general this air would be drawn under the door or through a slightly opened window If the room is air tight the fan will function poorly Supply cable entry Terminal block Fig 3 ...

Страница 4: ...e Live and Neutral supply wiring to the terminal block replace the terminal block cover and secure with screws 5 Secure the fan to the wall via the four screws and mounting holes 6 Replace the front panel and external shutter External shutter not supplied 1 Find a suitable location and cut the appropriate size diameter Ensure there are no cables or pipes above the ceiling when cutting 2 Remove the...

Страница 5: ...ut any maintenance ensure the power is switched OFF from the mains power supply 1 Wipe down the fascia and grilles with a wet soapy cloth only Do not allow water to have contact with the electrical parts such as the motor 2 Never use petrol benzene thinner or any other chemicals for cleaning the ventilation fan 3 Do not immerse resin parts into hot water over 60 C 4 Do not place hot objects near o...

Отзывы: