6. Only a licensed electrician should handle the installation.
SAFETY PRECAUTIONS
1. The appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the use of the appliance by a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with the appliance.
3. The structure to which the fan is to be mounted must be capable of supporting a weight of 20kg.
4. The fixing point on the ceiling, requires a solid bracing structure such as Timber noggins or joists.
The bracing should be butted up firmly and securely to the back of any non structural roofing panel
such as plaster or Gyprock to ensure safety and optimum performance of the fan.
5. The fan should be mounted so that the blades are at least 2.1m above the floor.
6. Only a licensed electrician should complete the installation.
7. WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
8. WARNING: Light and fan must be connected to the same phase. Before servicing, ensure both light
and fan circuits are disconnected.
• Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities. Contact your local government for information regarding the collection
systems available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the ground water and get into the food chain,
damaging your health and well-being.
2
WARNING:
FOR SAFE USE OF THIS FAN
,
AN ALL-POLE DISCONNECTION MUST BE
INCORPORATED INTO THE FIXED WIRING I
N
ACCORDANCE WITH THE WIRING RULES.
As outlined in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum electrical safety of
this standard.
Please note warranty will be void if installation is without an all-pole disconnection incorporated
in the fixed wiring in accordance with the wiring rules.
Example: If a fan is connected to a circuit that can be isolated via an all-pole safety switch at the
switchboard, then this is considered to be an all-pole disconnection to the ceiling fan electrical
circuit, meeting the requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch on the active of the receiver input of remote control must also be
included in the wiring, and located in the same room as the ceiling fan. (See wiring
diagram)