J. 

 This appliance is not intended for use by persons 

(including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person 
responsible for their safety. 

K. 

Young children should be supervised to ensure that 
they do not play with the appliance. 

 

DESCRIPTION 

The Response fan is a continuously running extract fan for kitchens, 
utility rooms, bathrooms and toilets.  
The product incorporates an airflow detection system that detects the 
installation duct resistance and maintains the correct fan speed to 
achieve the preset extract flow rate (model dependant). 
The incorporated LED display allows the installer to configure the fan to 
suit its installation. The display is also used to show the day logger and 
power run meter.  
The fan can be wall, window or panel/ceiling mounted.  
 
 

ACCESSORIES

 (not supplied) 

 

WALL FITTING KIT

 - A range of white (stock ref. 254102) or 

brown (stock ref. 254100) 100mm wall kits are available for 
installing into most walls using telescopic liners supplied. 

 

WINDOW KIT

 stock ref. 407927 

 

CEILING KIT

 stock ref. 407928 

 

150mm COVERSION KIT

 stock ref. 408680 

 

Decoration Frame 

stock ref. 474041 

 

A. INSTALLATION

 

 

 
SITING THE TRANSFORMER (SELV Models only) 

1.  The transformer must not be installed in a shower cubicle or 

enclosure. It must be sited away from direct sources of water spray 
and out of reach (1.5m) of a person using a fixed bath or shower. 

2. 

Site away from direct sources of heat. Ambient temperature range 
0 ºC to 40ºC. Do not site in an area containing excessive levels of 
grease. 

3. 

Decide where to site the transformer and fan and work out the 
required cable runs. 

Содержание Lo-Carbon Responce Series

Страница 1: ...tructions Stock Ref N 494143 Response 7 494144 Response 7 Pro 494150 Response 7 SELV 494149 Response 7 Pro SELV PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTION...

Страница 2: ......

Страница 3: ...installation within Zones 1 2 C The Fan should be provided with a local isolator switch capable of disconnecting all poles having a contact separation of at least 3mm D Ensure that the mains supply V...

Страница 4: ...the fan to suit its installation The display is also used to show the day logger and power run meter The fan can be wall window or panel ceiling mounted ACCESSORIES not supplied WALL FITTING KIT A ran...

Страница 5: ...lace the front panel EXTERIOR WALL MOUNTING 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necess...

Страница 6: ...enclosed or covered with insulation The fan is a class ll double insulated product and MUST NOT be earthed 1 Select and follow the appropriate wiring diagram Fig 1 2 3 or 4 5 6 2 Check all connection...

Страница 7: ...ll run for 15 minutes first showing the day logger then cycling between displaying Airflow rate Pro models only other models display speed setting Estimated duct pressure Pro models only Current RH HT...

Страница 8: ...c n normal LS overrun c Y comfort mode c n unl Enable disable lock code loc lock code enabled unl lock code disabled unlocked unl Menu lock code Up down selects current digit X moves to next digit 10c...

Страница 9: ...d rise function to detect rapid rises in humidity when the ambient rH is under the threshold setting If a rapid rise is detected the fan will increase in speed proportionally between the trickle and b...

Страница 10: ...errun duration of 5 minutes will take place This will override LS comfort mode boosting the fan immediately An activation when a Pullcord LS Light Switch boost is already active shall cancel overrun t...

Страница 11: ...press of the Mode button will return the fan to the commissioning menu D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTE...

Страница 12: ...us boost 1 with no trickle facility The fan is internally fused Fig 3 Continuous trickle with boost facility The fan is internally fused Fig 1 Continuous trickle with boost via pull cord The fan is in...

Страница 13: ...facility SELV models Fig 6 Continuous trickle with boost facility via LS or internal pullcord SELV models Fig 4 Continuous trickle with pullcord boost SELV models N L 1 Phase Supply 220 240V 50Hz FUSE...

Страница 14: ...g the controls Pull front panel as shown Loosen screws DO NOT REMOVE FROM GRILLE the screws are self retaining Pull inner grille away from housing as shown Open up the internal cover to access the spi...

Страница 15: ......

Страница 16: ...oduct rating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUAR...

Отзывы: