Vent-Axia Lo-Carbon PoziDry Compact Series Скачать руководство пользователя страница 6

 

6

In  many  installations  where  condensation  is  a  severe  problem;  it  is  recommended  to  run  the  fan  at  purge 
speed  for  a  couple  of  weeks  to  ventilate  the  house  thoroughly.    This  can  be  achieved  by  utilizing  the  LS 
input  option,  whereby  the  unit  will  run  on  Purge  setting  until  the  LS  signal  is  terminated.  To  achieve  this, 
connect the LS core of the integral mains flying lead to an LS input. 

 
It is the responsibility of the installer to ensure that appropriate speeds are selected. 
 
 

F. SERVICING AND MAINTENANCE 

 
The fan motor uses sealed ball bearings, and does not require further lubrication. 
Apart from filter change the Lo-Carbon Pozidry Compact contains no user serviceable parts. 
Under normal conditions; i.e. away from main roads and industrial areas it is recommended that the filter is checked 
annually and cleaned or replaced as necessary.  Otherwise change as required. 
The filter may be gently cleaned with a vacuum cleaner or washed in a soapy water solution and allowed to air dry 
before re-fitting. Do not dry the filter in a tumble dryer. 
 
Spare filters are available from Vent-Axia Sales Centres. 
 

Spares 

Stock Reference 

Filter 

447381 

Front cover 

447383 

Control PCB 

447385 

PSU PCB 

447386 

Motor/impeller 

447384 

Heating element (integral heater version 444767 only) 

447391 

 

 

Accessories

 

 

Elbow - 90 degree bend, (100 dia.) 

400752 

Duct - 2.0 m length, (100 dia.) 

5108250 

Wall fitting kit - white 

254102 

Wall fitting kit - brown 

254100 

Quick Fit 100mm wall grille - white 

563521 

Quick Fit 100mm wall grille - brown 

563541 

Quick Fit 100mm termination 

563535A 

Air replacement set (door grille) - ivory 

561401 

Air replacement set (door grille) - brown 

561400 

 
 

Installation Packs

 

 

 

 

Stock Reference: -

 

453546 

453547 

453548 

Quick-fit grill, white 

Wall fitting kit, brown 

HR 70WH Rnd-Rect Ad 

HR 060WH Vert 90

°

 bend 

Ind 040WH Elbow/Spgt 

HR 010WH 1m Flat Chnl 

HR 015WH 1.5m Flat Chnl 

HR 020WH Connector 

HR 050WH Horiz 90

°

 bend 

HR 122-H Chnl Clip 

 

Содержание Lo-Carbon PoziDry Compact Series

Страница 1: ...THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon PoziDry Compact Positive Pressure Ventilation Unit Stock Ref N Pozidry Compact 444767 With integral heater 444076 Without heater Installatio...

Страница 2: ...t ventilation unit designed to be installed in apartments taking fresh air from outside and supplying the air filtered into the building The Lo Carbon PoziDry Compact has two fully adjustable speed se...

Страница 3: ...d re fix to the other side of the unit in place of the metal front cover Carefully cut out the skinned area on the white plastic cover where the cable gland will now lie Rear entry inlet If rear entry...

Страница 4: ...bles when the terminal cover is replaced The switch cable and cable gland which are not supplied should be rated at 3 amps TO CONNECT A POWER SUPPLY Ensure the local AC power supply is isolated The pr...

Страница 5: ...le controls the heat setting for integral heater version 444767 WARNING THE BLUE POTENTIOMETER DRIVER SUPPLIED WITH THE UNIT MUST BE USED TO ADJUST THE POTENTIOMETERS Turning the potentiometers clockw...

Страница 6: ...er may be gently cleaned with a vacuum cleaner or washed in a soapy water solution and allowed to air dry before re fitting Do not dry the filter in a tumble dryer Spare filters are available from Ven...

Страница 7: ...Multi Speed Multi Speed Type HRS Recuperative Regenerative None None None Thermal Eff NA if none N A N A Max Flow Rate m3 h 122 40 122 40 Max Power Input W Max Flow Rate 49 80 49 80 LWA Sound Power Le...

Страница 8: ...n the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance...

Отзывы: