Vent-Axia Lo-Carbon MULTIVENT MVDC-MS Скачать руководство пользователя страница 11

 

11

 

 

PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)                                                                               

No 1254/2014) 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Name:  

Vent-Axia  

Vent-Axia  

Model ID (Stock Ref.) : 

MVDC-MS - 437634 - 

LDC 

MVDC-MSH - 443298 - 

LDC 

SEC Class 

SEC Value ('Average') 

-27.43 

-27.43 

SEC Value ('Warm') 

-11.92 

-11.92 

SEC Value ('Cold') 

-54.49 

-54.49 

Label Required? (Yes/No=Out of scope) 

Yes 

Yes 

Declared as: RVU or NRVU/UVU or BVU 

RVU/UVU 

RVU/UVU 

Speed Drive 

Variable Speed 

Variable Speed 

Type HRS (Recuperative, Regenerative, None) 

None  

None  

Thermal Eff: [ (%), NA(if none)] 

N/A  

N/A  

Max. Flow Rate (m3/h) 

335.88 

335.88 

Max. Power Input (W): (@Max.Flow Rate) 

41.70 

41.70 

LWA: Sound Power Level (dB) 

54.23 

54.23 

Ref. Flow Rate (m3/s) 

0.07 

0.07 

Ref. Pressure Diff. (Pa) 

200 

200 

SPI [W/(m3/h)] 

0.07 

0.07 

Control Factor & Control Typology: (CTRL/ Typology) 

  

  

Control Factor; CTRL 

0.65 

0.65 

Control Typology 

Local Demand Control 

Local Demand Control 

Declared: -Max Internal & External Leakage Rates(%) for BVUs or 
carry over (for regenerative heat exchangers only),                                                                       
-&Ext. Leakage Rates (%) for Ducted UVUs; 

<5% Internal, <5% 

External 

<5% Internal, <5% 

External 

Mixing Rate of Non-Ducted BVUs not intended to be equipped 
with one duct connection on either supply or extract air side; 

N/A 

N/A 

Position and description of visual filter warning for RVUs intended 
for use with filters, including text pointing out the importance of 
regular filter changes for performance and energy efficiency of 
the unit 

N/A 

N/A 

For UVUs (Instructions Install Regulated Supply/Extract Grilles 
Façade) 

In F&W 

In F&W 

Internet Address (for Disassembly Instructions) 

www.vent-axia.com 

www.vent-axia.com 

Sensitivity p. Var20/-20 Pa: (for Non-Ducted VUs) 

N/A 

N/A 

Air Tightness-ID/OD-(m3/h) (for Non-Ducted VUs) 

N/A 

N/A 

Annual Electricity Consumption: AEC (kWh/a) 

0.35 

0.35 

Annual Heating Saved: AHS (kWh/a) 

  

  

AHS: Average 

28.30 

28.30 

AHS: Warm 

12.80 

12.80 

AHS: Cold 

55.36 

55.36 

Содержание Lo-Carbon MULTIVENT MVDC-MS

Страница 1: ...CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon MULTIVENT MVDC MS MVDC MS H VENTILATION SYSTEMS Stock Ref N MVDC MS 437634B MVDC MS H 443298A Installation and Wiring Instr...

Страница 2: ...2...

Страница 3: ...should be provided with a 3A fused isolator switch capable of disconnecting all poles having a contact separation of at least 3mm 4 Ensure that the mains supply voltage frequency and phase complies wi...

Страница 4: ...y sensor uses one of the two available LS inputs the other remaining LS input can be used to switch the unit to Purge speed The MVDC MS H has the option to switch from Normal to Boost speed in effect...

Страница 5: ...ct diameter The larger the better Avoid having any bends filters or other obstructions within 250mm of the fan inlets and outlet 1 Position the MULTIVENT taking into consideration the position of the...

Страница 6: ...onnections are correct and that all terminal screws and cable clamps are securely fastened 4 To enable the fan to switch to boost or purge speed when a light is turned on connect the switched live con...

Страница 7: ...o the Purge LS connection on the mother board 5 The output 230V from the internal humidistat PCB is connected to the Boost LS terminal 6 Upon installation it is possible that the humidity controller w...

Страница 8: ...an isolated switched live connection to the LS connection on the power supply terminal block WARNING THE SWITCHED LIVE CONNECTION TO THE LS CONNECTION MUST BE ISOLATED FOR EXAMPLE USING AN ISOLATOR RE...

Страница 9: ...o achieve the stated energy efficiency rating with Local Demand Control LDC the arrangement below should be used The sensors S1 and S2 can be chosen based on the installation requirements Fuse L N E 1...

Страница 10: ...clockwise will increase the speed If a purge switch is installed this activates the unit at maximum speed Once the MVDC MS is commissioned apply white label over marked area containing Boost and Norm...

Страница 11: ...cal Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 Externa...

Страница 12: ...fied or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre...

Отзывы: