Jumper Configuration
Cooling and Heating - Heat Pump with O reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
Page 16
OUTPUTS
No Demand
With Demand
Cooling Mode
Heating Mode
O
Y
,
G
,
O
-
Y G
,
Y active in Heating
Jumper #1 (J1) should be set for
ELEC/HP
,
Jumper #2 (J2) should be set for
HP
,
and
Jumper #3 (J3) should be set for
O
for typical
heat pump operation.
Note: Thermostat does
not have Auxiliary Heat / Emergency Heat
capability.
INSTALLATION INSTRUCTIONS
T1035
O
J3
HP
J2
ELEC/HP
J1
PCB: 00597 Rev. AA
PCA: 00569 Rev.
O
B
GAS/ELEC
HP
GAS
ELEC/HP
BAT+
BAT-
1000
JFK
SKD
1000
JFK
SKD
1000
JFK
SKD
MODEL: T1035
082100009
C
R
H
Y
W
G
R
C
O
/B
47
1
47
1
47
1
R16
R18
C11
D7
N
N
E
A
C
P
J
A
P
4
S
2
2
0
-5
N
8
3
D
4
47
1
47
1
47
1
47
1
O
B
GAS/ELEC
HP
GAS
ELEC/HP
C
R
H
Y
J1
J2
J3
J1
J2
J3
Su
PM
I2:00
: