Venstar SKYPORT8 Скачать руководство пользователя страница 19

Display

14

1

 

Mode Indicators

  Selects the operational mode of the equipment. 

HEAT

 - Indicates the heating mode. 

COOL

 - Indicates the cooling mode. 

AUTO

 - Indicates the system will automatically changeover  

 

 between heat and cool modes as the temperature  

 

 varies. 

OFF 

- Indicates heating and cooling are turned off.

Clock with Day of the Week 

Indicates the current time and day. This clock is also used to  

program the time period schedules.

3

 

Room Temperature Display 

Indicates current room temperature.

4

 

Desired Set Temperature 

Indicates desired room temperature(s).

2

3

4
1

1

1
4

Содержание SKYPORT8

Страница 1: ...Owner s Manual Installation Instructions 7 Day Programmable Up to 2 heat 2 cool with Wi Fi and local API...

Страница 2: ...the dealer or an experienced radio orTV technician for help Notice Only peripherals complying with FCC limits may be attached to this equipment Operation with noncompliant peripherals or peripherals...

Страница 3: ...areil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionnement est soumis aux deux conditions suivantes 1 ce dispositif ne doit pas causer d interf rences et 2 ce dispos...

Страница 4: ...tup 17 Backlight Operation 18 Service Filter 19 Installer Setup 21 Programming a Daily Schedule 27 About Advanced Features Operation 29 Advanced Setup Table 34 Follow Installation Instructions careful...

Страница 5: ...he coolest temperature that the space should drop to before heating is turned on without regard to deadband Icon The word or symbol that appears on the thermostat display Mode The current operating co...

Страница 6: ...ons Turn off the power to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker or switch for disconnecting power to the furnace Remove the cover...

Страница 7: ...elow or the wiring diagrams that follow Wire from the Install on the old thermostat Function new thermostat terminal marked connector marked G or F Fan G Y1 Y Cooling Y1 W1 W Heating W1 O B Rh R M Vr...

Страница 8: ...t Y1 1st stage compressor relay Y2 2nd stage compressor relay C 24 VAC common CK1 Dry Contact IMPORTANT ThisthermostatrequiresbothR 24VACReturn andC 24VAC Common wiresbeconnectedtothebackplateterminal...

Страница 9: ...g mode When GAS is chosen the thermostat will not energize the Fan G terminal in heating When ELEC is chosen the thermostat will energize the fan in heating For Heat Pump Only When the GAS EL or HP di...

Страница 10: ...llation Instructions 1 Stage Heat 1 stage Cool 1 GAS O GAS EL ELEC B HP ON 2 3 1 GAS O GAS EL ELEC B HP ON 2 3 Dip Switch Settings R G Y1 W2 W1 O B Y2 C CK1 C W2 W1 O or B Y2 Y1 G R Thermostat HVAC Eq...

Страница 11: ...llation Instructions 2 Stage Heat 2 Stage Cool 1 GAS O GAS EL ELEC B HP ON 2 3 1 GAS O GAS EL ELEC B HP ON 2 3 Dip Switch Settings R G Y1 W2 W1 O B Y2 C CK1 C Y2 W1 O or B W2 Y1 G R Thermostat HVAC Eq...

Страница 12: ...X Heat 1 GAS O GAS EL ELEC B HP ON 2 3 1 GAS O GAS EL ELEC B HP ON 2 3 Dip Switch Settings Reversing valve choice O or B is dependant on the type of valve installed in the heat pump R G Y1 W2 W1 O B Y...

Страница 13: ...Heat 1 GAS O GAS EL ELEC B HP ON 2 3 1 GAS O GAS EL ELEC B HP ON 2 3 Dip Switch Settings Reversing valve choice O or B is dependant on the type of valve installed in the heat pump R G Y1 W2 W1 O B Y2...

Страница 14: ...2 Wire Kit ACC0436 1 GAS O GAS EL ELEC B HP ON 2 3 1 GAS O GAS EL ELEC B HP ON 2 3 Dip Switch Settings R G Y1 W2 W1 O B Y2 C CK1 C W2 W1 O or B Y2 Y1 G R Thermostat HVAC Equipment BROWN WHITE BLACK In...

Страница 15: ...s only occurs once during the Skyport account setup 3 A 6 digit code obtained from the thermostat is successfully entered into a Skyport account 4 Successfully download and install the Venstar Skyport...

Страница 16: ...Press the cooler button to setup Wi Fi Follow the instructions that appear on the Venstar Configurator App Connect to Skyport Although there is more than one way to create a Skyport account the steps...

Страница 17: ...Add thermostat A screen will pop up asking for a six digit code 5 Press the FAN button on the thermostat for 5 seconds 6 Press the Warmer button on the thermostat 7 A six digit code will appear on the...

Страница 18: ...Front Panel 13 1 Backlit Display 2 Up Warmer Down Cooler Buttons 3 Mode Button 4 Fan Button 5 Heat or Cool Indicator Heat Red Cool Green 1 3 2 4 5...

Страница 19: ...ly changeover between heat and cool modes as the temperature varies OFF Indicates heating and cooling are turned off 2 Clock with Day of the Week Indicates the current time and day This clock is also...

Страница 20: ...Indicates the thermostat is in the setup mode 7 Fan icon When only the Fan icon is displayed the fan is always on If the FAN is not on the display then the FAN is in Auto mode and will run only when n...

Страница 21: ...at and cool setpoints individually choose HEAT mode to adjust the heat setpoint and COOL mode to adjust the cool setpoint then return to AUTO mode Pressing the UP or DOWN buttons in Heat or Cool mode...

Страница 22: ...econds Time Schedule MODE Up for 2 seconds Emergency Heat Up FAN for 2 seconds Lockout Buttons MODE Up Down for 2 seconds Calibration MODE Down for 2 seconds Wireless Setup FAN for 5 Seconds Setting t...

Страница 23: ...ly at night Night Dimmer StartTime setup step 5 12 00 am to 12 00 am Night Dimmer StopTime setup step 6 12 00 am to 12 00 am User Setup Backlight Operation 18 Setup step 1 adjusts the clock Use the Wa...

Страница 24: ...ion Press FAN to reset Current Service Filter Calendar Days Setup Step 8 This counter displays the total number of calendar days that have elapsed since the counter was reset to help the user track Fa...

Страница 25: ...s SetpointLimits Setup Steps 11 13 When this feature is set to ON the Heat and Cool Setpoints may be restricted to preset levels in Setup Steps 12 and 13 MaximumHeatSetpoint Setup Step 12 MinimumCoolS...

Страница 26: ...e overridden and reset by pressing the WARMER or COOLER buttons on the thermostat Settings are No Limit 2 3 4 5 or 6 cycles per hour Compressor Minimum Off Minutes Setup Step 15 This feature allows th...

Страница 27: ...and is set to 2 degrees the room temperature will need to reach 66 before the heat turns on 2nd Stage Deadband Setup Step 18 Specifies the additional temperature difference after the first stage turns...

Страница 28: ...covery on the thermostat will attempt to reach the Morning setpoint temperature at the exact time programmed into the thermostat Comfort Recovery only works when the thermostat enters the Morning peri...

Страница 29: ...WAY Unoccupied settings FDD If FDD is selected when the dry contact is active EQUIP FAULT will appear on the display Dry Contact Operation Dry Contact Polarity setup step 24 Open Normally Open The dry...

Страница 30: ...hermostat such as a home automation system NOTE It is permissable to enable both Skyport and the local API at the same time Available Modes setup step 28 This setup step may restrict the use of this t...

Страница 31: ...press the WARMER and COOLER buttons together for two seconds The icon will appear on the display then release the buttons Press all three buttons in the order outlined above for keypad lockout To unlo...

Страница 32: ...he start time for each time period is adjustable The stop time for each time period is the start time for the next period Each time period or day part may be individually disabled Select the Day to Pr...

Страница 33: ...in the step where the Morning mode is specified Press MODE to advance to the next step Select Morning Heat Setpoint Press the WARMER or COOLER buttons to adjust the heat setpoint desired This step wi...

Страница 34: ...us the 1st stage deadband This 1st stage dead band is adjustable from 1 6 degrees and the default is two degrees The 2nd Stage of heat or cool is turned on when A The 1st Stage has been on for a minim...

Страница 35: ...cy Heat operation the thermostat will turn on the fan and the Aux strip heat when there is a demand for heat Also during Emergency Heat heatpump operation will be unavailable Exit Emergency Heat Follo...

Страница 36: ...tons The calibratedoffsetfromthe raw temperature readingisdisplayedinthelowerrightcorner Additionally onthisscreenyoumayviewthe SoftwareVersionintheupperleftcorner 4 After calibration is complete pres...

Страница 37: ...settings Any information entered prior to this reset will be permanently lost 1 Place the thermostat in the OFF mode 2 Press and hold the MODE button While holding the MODE button press and hold the...

Страница 38: ...STAT or both the thermostat and Wi Fi ALL C Select one of the above options using the Up or Down buttons D Press Fan for 2 seconds to restore the factory settings After factory settings are restored...

Страница 39: ...1 0 3 5 Minutes 5 16 Min Heat Cool Setpoint Difference 21 0 6 Degrees 2 17 1st Stage Deadband 22 1 6 Degrees 2 18 2nd Stage Deadband 22 0 10 Degrees 2 19 Minutes Between 1st and 2nd Stage 22 0 60 Minu...

Страница 40: ...HATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAININ...

Страница 41: ...Printed on recycled paper P N 88 1192 12 17...

Отзывы: