background image

REMOTE SENSOR

with OVERRIDE BUTTON

ACC-TSENWB

MODEL

SAFETY CONSIDERATIONS

Read  and  follow  the  manufacturer  instructions  carefully.    All  wiring  must  conform  to  local  and  national 
electrical codes.  Improper wiring or installation may damage the sensor.

Recognize safety information.  This is the safety alert symbol       .  When the safety alert symbol is present on 
equipment or in the instruction manual, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAUTION.  These words are used with the safety alert 
symbol.   DANGER identifies the most serious hazards which will result in severe personal injury or death.   
WARNING signifies a hazard which could result in personal injury or death.   CAUTION is used to identify 
unsafe practices which may result in minor personal injury or property damage.  

The Remote Sensor measures indoor air temperature and will send this information to the thermostat.   The 
sensor measures temperature with a range of -20° to 120° F.  The sensor also has an OVERRIDE button which 
will place the thermostat into the override mode for two hours.  For information on override operation please 
consult the Owner’s Manual of your thermostat.  

CORRECT LOCATIONS      The Remote Sensor should be mounted approximately five feet from the floor, close to or in a 
frequently used room, preferably on an inside partitioning wall or on a section of wall without pipes or ductwork.  Mount 
the sensor where temperature operating limits are within -20 to 120 F and the humidity operating range is within 0 to 95% 
relative humidity, non-condensing. 

INCORRECT LOCATIONS      The Remote Sensor should 

NOT

 be mounted close to a window, on an outside wall, or next to 

a door leading to the outside.   Do not mount the sensor in a location where it would be exposed to direct light and heat 
from a lamp, the sun, a fireplace, or any other temperature-radiating object which may cause a false reading.  Finally, do 
not mount the sensor close to or in direct airflow from supply registers or return air grilles and in areas with poor air 
circulation (such as behind a door or in an alcove).

Sensor Location

INDOOR INSTALLATION     Perform the following procedures to install 
the sensor:
   1.  Place the Remote Sensor wall plate on the wall.  Mark the
        mounting screw holes on the wall through the holes in the
        wall plate.
   2.  Drill two 3/16-in. mounting holes in the wall at the location 
        marked in Step 1.  
   3.  Mount the Remote Sensor wall plate to the wall with the 
        screws provided. 

Remote Sensor

Wall Plate

Through hole
for wires

Screw hole

Screw hole

Sensor Installation

Align  and  press  the  Remote  Sensor  circuit 
board onto the wall plate as shown.  Install the 
button onto the circuit board.

Note:   The OVERRIDE button can be disabled 
by  putting  non-conductive  tape  over  the 
switch  pad  before  installing  the  OVERRIDE 
button onto the circuit  board.

OVERRIDE 
button

Sensor Assembly

IMPORTANT:  READ ALL OF THESE INSTRUCTIONS BEFORE INSTALLING THE SENSOR.

GENERAL

©Venstar Inc. 8/11          

P/N 88-941     Rev. 1

White

Black

White

Black

White

Black

Отзывы: