3. PREPARE INSTALLATION

GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must
be plugged into an outlet that is properly installed and grounded.

Set the electrical power supply within the space covered by the decorative flue.
Position the outlet offset so that the power cord will not interfere with the round
duct. Place the outlet at a maximum distance of 33

7

/

16

” from where the cord exits

from the hood (see illustration alongside). Make sure this does not interfere with
a mounting bracket fastening area or with the decorative flue (where the flue
touches the wall). 

4. WIRING INSTALLATION

Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This range
hood must be properly grounded. Turn off electrical power at service entrance before wiring. 

HE00

8

6

Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an
extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

33

7

16

” 

MAX

.

Make sure that the following items are included:
1 - Hood
1 - Decorative Flue Assembly (lower and upper flues)
1 - Lower Flue Mounting Bracket
1 - Hood Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Parts Bag containing:

8 - No. 8 x 7/16” Mounting Screws
7 - No. 8 x 1½” Mounting Screws
9 - Drywall Anchors
2 - Washers
2 - No. 8 x 1¼” Mounting Screws
4 - Aesthetic Washers
4 - M4 x 0.7” Mechanical Flat Head Screws

NOTE: If need be, discard extra screws.

2 - Aluminum Grease Filters
1 - 6” Round Adapter/Damper
1 - Curved glass (VJ603302SS only) or stainless steel plate (VJ604302SS only)
1 - Installation Manual

HR00

3

1A

D

ECORATIVE

FLUE

L

OWER

 

FLUE

MOUNTING

 

BRACKET

H

OOD

MOUNTING

 

BRACKET

U

PPER

 

FLUE

MOUNTING

 

BRACKET

6

 R

OUND

 

ADAPTER

/

DAMPER

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.

WARNING

!

WARNING

!

Содержание Jazz VJ604302SS

Страница 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 7 AND 8 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv c...

Страница 2: ...ette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for th...

Страница 3: ...es To reduce the risk of fire use only metal ductwork 2 MEASURE INSTALLATION The minimum hood distance above cooktop MUST NOT BE less than 26 A maximum of 30 above cooktop is highly recommended for be...

Страница 4: ...ce before wiring HE0086 Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to w...

Страница 5: ...er hidden utilities 6 INSTALL UPPER FLUE MOUNTING BRACKET Center the bracket over the hood location and place it flush with the ceiling Make sure that the slots of the upper flue bracket point down Us...

Страница 6: ...ove protective plastic film covering the lower flue only 8 Install the lower flue bracket to its flue using 2 no 8 x 7 16 mounting screws make sure that the slots point up Fig 2 9 Carefully place both...

Страница 7: ...57 WARNING In order to prevent the risk of personal injury the halogen lamps must be cooled down before removing them CAUTION Do not touch replacement bulb with bare hands LIGHT BULB COVER 1 To remove...

Страница 8: ...10 OPERATION continued 1 TIME DELAY 2 Functions Time Setting This button is used to set time when lighting and blower are not in use Time is displayed in 24 hour cycle To set time press the push butto...

Страница 9: ...drywall anchors 2 washers 2 no 8 x 1 mounting screws 4 aesthetic washers 4 M4 x 0 7 mechanical flat head screws 1 9 Not illustrated HL0128 7 1 2 3 4 3 5 6 REPLACEMENT PARTS AND REPAIRS In order to en...

Страница 10: ...ice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit remo...

Отзывы: