Venmar FAE115 Скачать руководство пользователя страница 2

This manual uses the following symbols to emphasize particular information:

NOTE: Indicates supplementary information needed to fully complete an instruction.

2

ABOUT THIS MANUAL

WARNING

Identifies an instruction which, if not followed, might cause serious
personal injuries including possibility of death.

!

CAUTION

Denotes an instruction which, if not followed, may severely damage
the unit and/or its components.

Venmar Ventilation Inc. or vänEE Canada warrants to the original consumer purchaser
of its products, that such products will be guaranteed against all manufacturing
defects and defective material for a period of three (3) years and a lifetime warranty
on the heat recovery core (used under normal conditions).

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. OR vänEE CANADA
WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL 
PURCHASE PRICE OF A 

FURNACE AIR EXCHANGER WITH HEAT RECOVERY

,

NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.

During the period stated above, Venmar Ventilation Inc. or vänEE Canada will, at
its opinion, repair or replace, without charge, any product or part which is found
to be defective under normal use and service. This warranty does not cover 

a)

normal

maintenance and service, 

b)

any products or parts which have been subject to misuse,

negligence, accident, improper maintenance or repairs made by other than Venmar
Ventilation Inc or vänEE Canada, or 

c)

a faulty installation or installation contrary to 

recommended installation instructions.

The duration of any implied warranty is limited to the 3-year period as specified
for the express warranty. Some states or provinces do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.

VENMAR VENTILATION INC. OR vänEE CANADA'S OBLIGATION TO REPAIR OR
REPLACE AT VENMAR OR vänEE'S OPTION, SHALL BE THE PURCHASER'S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR OR vänEE SHALL
NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
SOME STATES OR PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION
OR EXCLUSION MAY NOT APPLY TO YOU.

This warranty gives you specific legal rights and you may also have other rights, which
vary from state or province to another. This warranty supersedes all prior warranties.

To contact Venmar Ventilation Inc. or vänEE Canada warranty service call 
1-800-567-3855 in Canada and United States.

In order to qualify for a warranty claim, the owner of a Furnace Air Exchanger with
heat recovery must have the model and serial number along with a proof of the
original purchase date. At the time of requesting service, describe the nature of
any defect in the product or part.

In case of discrepancies between the english version of the warranty and the
french version, the english version will prevail.

WARRANTY

Содержание FAE115

Страница 1: ...your installer 04423 07 04 00 Furnace Air Exchanger with Heat Recovery CANADIAN MODELS US MODELS FAE115 vFAE115 uFAE115 FAE115M vFAE115M uFAE115M INSTALLER LEAVE THIS MANUAL TO HOMEOWNER Customer Ser...

Страница 2: ...accident improper maintenance or repairs made by other than Venmar Ventilation Inc or v nEE Canada or c a faulty installation or installation contrary to recommended installation instructions The dur...

Страница 3: ...ting and Mounting the Unit 6 4 2 Connecting Ducts to the Unit 7 4 3 Installing Exterior Hoods 7 4 4 Connecting the Drain 8 5 0 AIR FLOW BALANCING 9 6 0 YOUR UNIT 11 6 1 Unit Description 11 6 2 Heat Re...

Страница 4: ...3 Canada 04455 US 04434 VL0004 2 2 1 1 3 NOTE Unit in normal position Can also be installed upside down FAE115M uFAE115M vFAE115M FAE115 uFAE115 vFAE115 2 0 TECHNICAL DATA 2 1 AIR DISTRIBUTION VF0014...

Страница 5: ...ows cfm Pressure in water gauge VG0031A Stale air Fresh air 0 05 0 15 0 25 110 2 3 DIMENSIONS VK0028 22 562 573 mm 27 250 692 mm 1 500 38 mm 2 225 57 mm 20 000 508 mm 14 500 368 mm 6 000 152 mm NOTE T...

Страница 6: ...6 6 18 Figure 2 4 0 INSTALLATION 4 1 LOCATING AND MOUNTING THE UNIT Choose an appropriate location for the unit So as to provide easy access to the interior cabinet Close to an exterior wall so as to...

Страница 7: ...water dripping due to condensation on the exterior surface of the duct a b c d e f VJ0001 VJ0002 VJ0003 VJ0004 VJ0005 CAUTION Make sure that the vapor barrier on the insulated ducts does not tear duri...

Страница 8: ...op in the tube to prevent the unit from drawing unpleasant odors from the drain source Make sure this loop is situated BELOW the T as shown This will prevent water from being drawn back up into the un...

Страница 9: ...w Collars VP0005 VP0008 A 36 914mm 12 304mm OR B 12 304mm F G Flow collar Seal all the unit ductwork with tape Close all windows and doors Turn off all exhaust devices such as range hoods dryers and b...

Страница 10: ...is less than the reading at A then go back and adjust the exhaust balancing damper G to equal the fresh air flow 5 If the furnace has a low speed option select the low speed option and check if the fr...

Страница 11: ...is heat recovery process is accomplished in such a way that the stale air is never mixed with the fresh air Example in winter VF0015 INSIDE OUTSIDE STALE AIR TO OUTSIDE 25 C 77 F FRESH AIR FROM OUTSID...

Страница 12: ...t turn off your unit and unplug it in the following situation If you owns a FAE115 a uFAE115 or a vFAE115 model this Section doesn t concern your unit Please refer to the next Sections This wall contr...

Страница 13: ...ishwasher is possible but the aluminum frame might tarnish 4 Remove and clean the heat recovery core Let it soak in a mixture of cold or lukewarm water and mild soap dishwashing liquid Rinse thoroughl...

Страница 14: ...plugged in models FAE115M uFAE115M See if the transformer is receiving and vFAE115M only power from the house circuit breaker 2 Condensation on windows Adjust the humidity control knob as Air too hum...

Отзывы: