Use the following procedure for connecting the insulated flexible ducts to the ports on the unit 
(exhaust to outside and fresh air from outside).

a)

  Pull back the insulation to expose the flexible duct.

b)

  Connect the interior flexible duct to the opening using a duct tie.

c)

  Carefully seal the connection with duct tape.

d)

  Pull the insulation over the joint and tuck it between the inner and outer rings of double collar.

e)

  Pull the vapor barrier over the insulation and over the outer ring of the double collar.

f)

  Apply duct tape to the joint making an airtight seal. Avoid compressing the insulation when 

you pull the tape tightly around the joint. A compressed insulation loses its R value and 
also causes water dripping due to condensation on the exterior surface of the duct.

CAUTION

Make sure that the vapor barrier on the insulated ducts does not tear during 
installation.

a)

VJ0001

VJ0002

VJ0003

VJ0004

VJ0005

b)

c)

d), e)

f)

4.3 E

XTERIOR

 H

OODS

 I

NSTALLATION

Choose an appropriate location for the exterior hoods installation:
 

•  At a minimum distance of 6 feet between the hoods to avoid cross-contamination

 

•  At a minimum distance of 18 inches from the ground

Make sure the intake hood is at least 6 feet away from any of the following:
 

•  Dryer exhaust, high efficiency furnace vent, central vacuum vent

 

•  Gas meter exhaust, gas barbecue-grill

 

•  Any exhaust from a combustion source

 

•  Garbage bin and any other source of contamination

Refer to figure below for connecting the insulated duct to the hoods. An “Anti-Gust Intake 
Hood” should be installed in regions where a lot of snow is expected to fall.

E

XHAUST

 

HOOD

I

NTAKE

 

HOOD

18"

6" Ø

O

PTIONAL

 

DUCT

 

LOCATION

18"

6"

18"

6"

Содержание FAE 125M

Страница 1: ...ION AND USER MANUAL VB0134 FURNACE AIR EXCHANGER WITH HEAT RECOVERY MODELS ADDRESS OF YOUR INSTALLER FAE125 VFAE125 FAE 125M VFAE125M INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER CUSTOMER SERVICE PHONE...

Страница 2: ...r installation contrary to recommended installation instructions The duration of any implied warranty is limited to the 2 year period as specified for the express warranty Some jurisdictions do not al...

Страница 3: ...ufacturer at the telephone number listed in the warranty 10 When performing installation servicing or cleaning the unit it is recommended to wear safety glasses and gloves 11 Servicing shall be done b...

Страница 4: ...INSTALLATIONS 8 4 INSTALLATION 8 10 4 1 LOCATING AND MOUNTING THE UNIT 8 4 2 CONNECTING DUCTS TO THE UNIT 9 4 3 INSTALLING EXTERIOR HOODS 9 4 4 CONNECTING THE DRAIN 10 5 AIR FLOW BALANCING 10 12 6 WA...

Страница 5: ...tically reduce the performance level of your unit which will result in premature failing The manufacturer recommends to contact a certified service depot for all replacement parts and repairs NO PART...

Страница 6: ...is accomplished in such a way that the stale air is never mixed with the fresh air Example in winter VF0015 EXHAUST AIR FROM BUILDING 60 C 140 F DURING HEATING MODE FRESH AIR TO BUILDING 35 C 95 F FRE...

Страница 7: ...ERFORMANCE CHART These following curves illustrate the air volume through the units for a typical installation A typical installation is close to an exterior wall in order to shorten the insulated duc...

Страница 8: ...insulated VH0080 4 INSTALLATION 4 1 LOCATING AND MOUNTING THE UNIT Choose an appropriate location for the unit So as to provide easy access to the interior cabinet Close to an exterior wall so as to l...

Страница 9: ...s R value and also causes water dripping due to condensation on the exterior surface of the duct CAUTION Make sure that the vapor barrier on the insulated ducts does not tear during installation a VJ0...

Страница 10: ...in source Make sure this loop is located OVER the T as shown Run the tube to the floor drain or to an alternative drain pipe or pail IMPORTANT If using a pail to collect water locate the tube end appr...

Страница 11: ...in place temporarily Balancing Procedure 1 Set the furnace blower to maximum speed 2 Place the magnehelic gauge on a level surface and adjust it to zero 3 Connect tubing from gauge to flow collar in e...

Страница 12: ...e to the other side of the unit and take the second reading 6 WALL CONTROL FAE125M AND VFAE125M ONLY 6 1 INSTRUCTIONS REGARDING WALL CONTROL The wall control works with a dehumidistat that allows you...

Страница 13: ...top tray of the dishwasher is possible but the aluminum frame might tarnish E Slide out and wash the heat recovery core Let it soak in a mixture of cold or lukewarm water and mild soap dishwashing liq...

Страница 14: ...s air too humid Adjust the humidity control knob as per instructions see Section 6 FAE125M and VFAE125M models only Leave curtains half open to allow air circulation Store all firewood in a closed roo...

Отзывы: