8. Installation of the Controls
(cont’d)
8.2.3
Main Control Electrical Connection
8.2 I
NSTALLATION OF THE
M
AIN
C
ONTROL
(
CONT
’
D
)
1.
Connect the wires to their corresponding position inside the electrical
compartment. Make sure the connections of the unit and of the wall control
correspond exactly.
2.
Connect the optional controls (if applicable) by referring to section 8.3.
3.
Do the appropriate connection to the furnace (if applicable) by referring to Section 8.4.
4.
NOTE:If you are in a cold region (zone A or B, as defined in Section 3), set up “extended defrost” by removing jumper
JU1F on the main circuit board inside the electrical compartment (see Section 9).
5.
Plug in the unit and do the “overall verification” of the system as described in Section 11.
F F I OCOL Y R G B
VE00
8
4
9
8
7
6
5
4
3
2
1
OL
OC
I
1 4 7
2 5
8
3
6 9
J
3
MAIN PC BOARD
PU
S
H-BUTTON
S
WITCHE
S
J1
0L
0C
I
VE0176A
REAR VIEW
DEHUMIDI
S
TAT or
CRANK TIMER
8.3 O
PTIONAL
C
ONTROLS
E
LECTRICAL
C
ONNECTION