6.
M
OUNT THE WALL CONTROL TO THE WALL
.
P
LUG THE VENTILATION UNIT AND TEST THE
WALL CONTROL OPERATION
.
DECO-TOUCH WALL CONTROL INSTALLATION AND OWNER GUIDE
THIS WALL CONTROL CAN BE USED WITH THE FOLLOWING VENTILATION UNITS:
VENMAR AVS SOLO, DUO, HE, COMPACT, CONSTRUCTO 1.0*, HRV
AND
ERV EKO 1.5, NOVOFIT, KUBIX HRV PLUS
AND
KUBIX ERV
VÄNEE GOLD SERIES, HE*, 60H*, HRV
AND
ERV 90H-V ECM, NOVO+, VIGÖR HRV PLUS
AND
VIGÖR ERV
IT IS NOT COMPATIBLE WITH OTHER VENTILATION UNITS.
*CONSTRUCTO 1.0 AND VÄNEE 60H BUILT IN AUGUST 2008 AND LATER, AND VÄNEE HE BUILT IN JULY 2006 OR LATER. THE DATE CODE ON
THE UNIT IS PART OF ITS 13-DIGIT SERIAL NUMBER. FOR EXAMPLE, THE SERIAL NUMBER XXXX
0708
XXXXX, WHERE 07 IS THE YEAR AND
08 THE MONTH (AUGUST); THE DATE CODE IS ALWAYS THE FIFTH, SIXTH, SEVENTH AND EIGHTH DIGITS.
A
LWAYS DISCONNECT THE UNIT BEFORE MAKING ANY CONNECTIONS
. F
AILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE
TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT
.
WARNING
!
F
AILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT
:
• N
EVER INSTALL MORE THAN ONE MAIN WALL CONTROL PER VENTILATION UNIT
.
• K
EEP CONTROL LOW VOLTAGE WIRING AT LEAST
1
FOOT
(305
MM
)
AWAY FROM MOTORS
,
LIGHTING BALLAST
,
LIGHT DIMMING CIRCUIT AND POWER
DISTRIBUTION PANEL
. D
O NOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING
.
• E
NSURE THE WIRES ARE SECURELY CONNECTED
.
CAUTION
W
ALL
C
ONTROL
I
NSTALLATION
5.
S
TRIP THE END OF THE CABLE TO ACCESS THE
4
WIRES
. S
TRIP THE END OF EACH WIRE
.
U
SING A SMALL FLAT BLADE SCREWDRIVER
,
CONNECT EACH WIRE TO ITS CORRESPONDING
TERMINAL ON THE BACK OF THE WALL
CONTROL
: YELLOW
WIRE TO
“Y”, RED
WIRE
TO
“R”, GREEN
WIRE TO
“G”
AND
BLACK
WIRE TO
“B”.
Y
B
G
R
VE0243
2.
C
UT A
2
7
/
8
”
X
1 ³/
8
”
HOLE IN WALL AT A
CONVENIENT LOCATION FOR THE WALL CONTROL
.
R
OUTE THE CABLE FROM THE UNIT TO THIS
HOLE
.
NOTE:D
IMENSIONS SHOWN ARE FOR AN
INSTALLATION WITHOUT WALL BOX
.
1.
U
NPLUG THE VENTILATION UNIT FROM POWER SOURCE
.
VC0115
3.
T
EMPORARILY PLACE THE SWITCH OVER THE
HOLE AND MARK BOTH MOUNTING SCREW
HOLE POSITIONS
.
4.
R
EMOVE THE SWITCH
,
DRILL BOTH SCREW
HOLES
(Ø 3/16”)
IN WALL AND INSERT WALL
ANCHORS
(
INCLUDED
).
VC0116A
Ø 3/16”, typ.
OR
W
ALL
C
ONTROL
U
SE
B
ACKLIGHT
I
F THE BACKLIGHT IS NOT ILLUMINATED
,
THE FIRST BUTTON PRESSED
(
NO MATTER
WHICH BUTTON
)
SHALL TURN ON THE BACKLIGHT
. T
HE BACKLIGHT REMAINS ILLUMINATED
FOR
10
SECONDS AFTER THE LAST BUTTON PRESSED
.
O
PERATING
M
ODES
OFF
P
UT THE UNIT ON STAND
-
BY MODE
,
SO IT WILL ONLY RESPOND TO
OVERRIDE WALL CONTROLS
(
IF PRESENT
). O
N
LCD
SCREEN
,
ONLY THE
H
OUSE
IS VISIBLE
SHOWING THE
CONTROL
IS
POWERED
ON
.
T
HIS IS THE FACTORY DEFAULT MODE
.
RECIRC
A
IR IS RECIRCULATED INSIDE THE HOUSE AT HIGH SPEED
.
20
MIN
/
H
T
HE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE HOUR
CYCLE AS FOLLOWS
: OFF
FOR
40
MIN
. (
OR RECIRCULATION ON
HIGH SPEED FOR
40
MIN
.,
SEE NEXT
S
ECTION ON BACK PAGE
)
AND
THEN EXCHANGE AIR DURING
20
MIN
.
ON LOW SPEED
. R
EPEAT CYCLE
AFTER THE
20
MIN
.
OF AIR EXCHANGE
.
MIN
A
IR IS EXCHANGED WITH THE OUTSIDE ON LOW SPEED
.
MAX
A
IR IS EXCHANGED WITH THE OUTSIDE ON HIGH SPEED
.
O
PERATING
M
ODES
(
CONT
’
D
)
T
O CHANGE THE OPERATION MODE OF THE VENTILATION UNIT
,
PRESS
THE
UP
OR
DOWN
ARROW BUTTON
. O
PERATING MODE LABEL WILL
THEN SCROLL UP OR DOWN ON
LCD
SCREEN
.
09947
REV
. B