background image

W

ALL

C

ONTROL

U

SE

(

CONT

D

)

H

OW TO SET THE RELATIVE HUMIDITY

(RH) 

LEVEL AND CHOOSE BETWEEN

OFF 

IN STANDBY OR

RECIRCULATION

IN STAND

-

BY

S

ETTING THE RELATIVE HUMIDITY LEVEL ALLOWS TO SELECT THE MAXIMUM DESIRED

INDOOR HUMIDITY LEVEL

(

IN PERCENTAGE

). T

HIS VALUE WILL BE USED TO START THE

DEHUMIDISTAT OVERRIDE

(

AIR EXCHANGE IN HIGH SPEED

).

P

RESS AND HOLD

OK 

FOR

SEC

TO

ACCESS THE SETTINGS MENU

. T

HE

BACKLIGHT WILL BE ACTIVATED DURING

ALL THE PROCEDURE

.

T

HE

R

ELATIVE HUMIDITY ARROW AND

VALUE WILL FLASH

(

DEFAULT SETTING

:

45%). 

U

SE

UP 

OR

DOWN 

ARROW

TO CHANGE THE VALUE

. T

HE

VALUE

CHANGES

BY

1% 

INCREMENTS

. L

OWER VALUE

:

30%. U

PPER VALUE

: 55%.

S

TILL FLASHING

.

P

RESS

OK 

BUTTON TO ACCEPT THE

NEW VALUE AND GO TO NEXT SETTTING

.

R

ECIRCULATION ARROWS ARE TURNING

AND

rE 

FLASHES TO SHOW THAT

RECIRCULATION²

IS IN STANDBY

.

P

RESS

OK 

BUTTON

TO ACCEPT AND QUIT

SETTING MENU

.

OR

U

SE

UP 

OR

DOWN

ARROW TO CHANGE TO

RECIRCULATION

IN

STANDBY

.

T

WO LINES ARE FLASHING TO SHOW

THAT

OFF¹ 

IS IN STAND BY

(

DEFAULT

CONFIGURATION SETTING

).

OR

OR

R

ESETTING

M

AINTENANCE

I

NDICATOR

: P

RESS SIMULTANEOUSLY ON

BOTH ARROW BUTTONS

, M

AINTENANCE INDICATOR WILL DISAPPEAR

FROM

LCD 

SCREEN

.

AND

M

AINTENANCE

I

NDICATOR

T

HE MAINTENANCE INDICATOR IS REPRESENTED

BY AN

IN A ROUNDED TRIANGLE

AT THE TOP

OF THE HOUSE

(

SEE BESIDE

). I

F THIS INDICATOR

IS

FLASHING

PERFORM

THE

SEMI

-

ANNUAL

MAINTENANCE

AND IF IT IS NOT FLASHING

PERFORM

THE ANNUAL MAINTENANCE

(

REFER TO THE

VENTILATION UNIT USER GUIDE

).

D

EHUMIDISTAT

O

VERRIDE

S

ELECTION

I

N THE OPERATING MODES

MIN, MAX, 20 

MIN

/

H AND

RECIRC, 

THE USER CAN

SELECT A DEHUMIDISTAT OVERRIDE SO THAT IF THE RELATIVE HUMIDITY

(RH) 

IN THE

HOUSE EXCEEDS THE

RH 

SETTING PREVIOUSLY STORED

THE VENTILATION UNIT WILL

EXCHANGE IN HIGH SPEED UNTIL THE TARGET INDOOR

RH 

SETTING IS REACHED

.

A

N AIR EXCHANGER IS NOT A DEHUMIDIFIER

BUT IT CAN CHANGE THE INDOOR RELATIVE

HUMIDITY BY BRINGING IN DRIER OR MORE HUMID AIR FROM OUTSIDE DURING NON

HEATING SEASON

. T

HE DEHUMIDISTAT OVERRIDE FUNCTION IS USEFUL TO REDUCE

INDOOR

RH 

WHEN THE OUTDOOR AIR IS COOL AND DRY DURING THE HEATING SEASON

.

S

ELECT A TARGET

RH 

BETWEEN

30% 

AND

55% 

ACCORDING TO YOUR COMFORT

.

W

HEN OUTDOOR RELATIVE HUMIDITY IS HIGH

(

E

.

G

IN SUMMER

), 

TURN OFF THE OVERRIDE

BY PRESSING

OK 

UNTIL THE

RH 

DISPLAY DISAPPEARS

W

HEN THE DEHUMIDISTAT OVERRIDE IS ACTIVATED

THE

AUTO 

INDICATOR

WILL APPEAR ON

LCD 

SCREEN TO SHOW THAT THE ACTUAL MODE IS

BEING OVERRIDDEN

. A

LSO

THE RELATIVE HUMIDITY APPEARS

(

IF IT WAS

NOT SHOWN

SEE EXAMPLE BESIDE

). O

NCE THE TARGET HUMIDITY

LEVEL IS REACHED

THE UNIT GOES BACK INTO ITS ORIGINAL OPERATING

MODE AND

AUTO 

DISAPPEARS FROM

LCD 

SCREEN

.

NOTE:

I

F THE ACTUAL MODE IS

MAX, 

ONLY THE RELATIVE HUMIDITY LEVEL

APPEARS ON SCREEN

; AUTO 

LABEL WILL NOT APPEAR

.

T

O ENGAGE THE DEHUMIDISTAT OVERRIDE

PRESS

OK. T

HE ACTUAL INDOOR

RH 

AND

THE

%HUM 

LABEL APPEAR ON

LCD 

SCREEN

.  

NOTE:

I

F THE ACTUAL

RH 

IS LESS THAN

20%, 

THEN THE HUMIDITY INDICATOR

WILL DISPLAY

“LO”, 

AND IF THE ACTUAL

RH 

IS GREATER THAN

80%, 

THEN

THE HUMIDITY NDICATOR WILL DISPLAY

“HI”.

T

O TURN OFF THE DEHUMIDISTAT OVERRIDE

PRESS

OK 

AGAIN

. T

HE

RH 

AND

%HUM

DISPLAY WILL DISAPPEAR FROM

LCD 

SCREEN

P

OWER

F

AILURE

A

FTER A POWER FAILURE

THE WALL CONTROL RETURNS TO ITS ORIGINAL OPERATION

MODE

. A

LL SETTINGS ARE KEPT IN MEMORY

.

E

RROR

C

ODES

I

F THERE IS A PROBLEM WITH THE WALL CONTROL

AN ERROR CODE WILL APPEAR ON

THE SCREEN

IT COULD BE

E1, E3 

OR

E7. I

S THIS SITUATION OCCURS

UNPLUG

 

THE

VENTILATION

 

UNIT

 

FOR

 20 

SECONDS

 

AND

 

THEN

 

REPLUG

 

IT

. I

F THE ERROR CODE IS STILL

PRESENT

PLEASE CALL YOUR INSTALLER

.

P

RESS

OK 

BUTTON TO ACCEPT AND

QUIT SETTING MENU

.

1OFF 

IN STAND BY

:

O

N

20 

MIN

/

H MODE

THE VENTILATION UNIT IS

OFF 

DURING

40 

MINUTES AND EXCHANGE AIR WITH THE OUTSIDE ON LOW SPEED

DURING THE REMAINING

20 

MINUTES OF THE HOUR

. T

HIS IS THE

DEFAULT VALUE

.

2RECIRCULATION

IN STAND BY

: O

N

20 

MIN

/

H MODE

THE VENTILATION UNIT

RECIRCULATES THE INSIDE AIR FOR

40 

MINUTES

ON HIGH SPEED AND EXCHANGE AIR WITH THE
OUTSIDE ON LOW SPEED DURING THE REMAINING

20 

MINUTES OF THE HOUR

.

Отзывы: