Venmar CONNAISSEUR CC32I SERIES Скачать руководство пользователя страница 9

9

11. REINSTALL BLOWER (HORIZONTAL DISCHARGE ONLY)

Position the blower on the higher (

A

) or lower (

B

) back wall 

discharge as determined previously.
Using a 5/16” socket, or a Robertson or a Phillips no. 2 
screwdriver and the 4 previously removed screws, secure the 
blower to the hood.
NOTE:  In order to ease installation, before mounting the blower, 
 

 

prepare the screw holes by screwing all 4 screws without 

 

 

the blower, then remove and mount the blower.

HD0387

A

B

R

IGHT

 

SIDE

 

MOUNTING

 

SCREW

 

LOCATIONS

R

IGHT

 

SIDE

 

MOUNTING

 

SCREW

 

LOCATIONS

HE0085

Plug the blower back in and plug hood power cord into the outlet.

12. PLENUM INSTALLATION (NON-DUCTED INSTALLATION ONLY)

HA0077

Using 4 no. 8 x 3/8” provided screws, assemble the 8” round adapter to the lower plenum plate.

HD0382

A

A

Carefully align the upper plenum plate central notch with the line traced in step 9 (see inset at 
right) and place it flush to the ceiling. Use the plate as a template to mark the position (

A

) of its 

screws.
NOTE:  To ease installation, there are many screw configurations: 6 in ceiling and 2 in wall, on each 
 

 

side. Only 4 screws are needed to hold the top plenum plate.

Insert the included drywall anchors in the marked holes, then secure the upper plate using 
4 no. 8 x 3/4” screws and washers (included with 09025 non-duct kit). Make sure the plate is tight 
against the wall and ceiling.

HD0388

Assemble the lower plenum plate and transition assembly to the upper plate by inserting both 
tabs of the top plenum plate to their corresponding slots in lower plenum plate. Secure the plenum 
assemby using 2 no. 8-18 x 3/8” screws (included).

Содержание CONNAISSEUR CC32I SERIES

Страница 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 AND 14 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Страница 2: ...oper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and va...

Страница 3: ...SUPPLIED WITH 09025 NON DUCT KIT 8 ROUND STANDARD DUCT 8 ROUND ADJUSTABLE ELBOW OPTIONAL MODEL 643 8 ROUND WALL CAP MODEL 401 STANDARD 3 X 10 DUCT CC32I SERIES RANGE HOOD SINGLE BLOWER SUPPLIED WITH...

Страница 4: ...he unit it is recommended to wear safety glasses and gloves 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION Non duct kit model 09025 is required for a non ducted installation 2 2 DUCTED INSTALL...

Страница 5: ...TH HOOD 30 WIDTH HOOD VERTICAL DISCHARGE OR NON DUCTED INSTALLATION HORIZONTAL DISCHARGE HD0391 1 2 4 CHOOSE THE OPENING VERTICAL DISCHARGE OR NON DUCTED INSTALLATION Using a Robertson or a Phillips n...

Страница 6: ...ed to receive the adapter Before performing the installation make sure the adapter fits easily in the duct If this hood replaces another one please note that the location of the air exhaust can vary f...

Страница 7: ...ounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be pl...

Страница 8: ...of its screws Drill the 3 screw holes using a 3 16 drill bit Insert the included drywall anchors into the drilled holes 1 per hole Secure the upper flue bracket to the wall using 3 no 8 x 3 4 screws...

Страница 9: ...s assemble the 8 round adapter to the lower plenum plate HD0382 A A Carefully align the upper plenum plate central notch with the line traced in step 9 see inset at right and place it flush to the cei...

Страница 10: ...Y VERTICAL DISCHAGE Plug hood power cord into the outlet Slide a 8 metal round duct over the adapter damper on the hood Use metal foil duct tape to seal the joint HJ0037 NON DUCTED INSTALLATION Plug h...

Страница 11: ...move protective plastic film covering the lower flue only then just peel off the plastic film covering both top corners of the upper decorative flue Position the lower flue rear notches down the ones...

Страница 12: ...the plenum sides using 2 no 8 x 1 4 screws included per side NOTE Ceiling not shown in illustration to ease understanding HA0079 ALL INSTALLATIONS Remove protective plastic film covering the upper fl...

Страница 13: ...metal filters in the dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions but this will not affect fi...

Страница 14: ...B START STOP SPEED SELECTION SWITCH Press the switch corresponding to the desired blower speed from 1 for low speed to 4 for high speed The chosen switch will light To turn off the blower press once m...

Страница 15: ...e the product will be repaired or replaced at Venmar s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar...

Страница 16: ...OUND CHARCOAL FILTERS 2 PER KIT 1 17 09016 ROUND CHARCOAL FILTER SUPPORT 2 18 09017 8 ROUND METAL FLEXIBLE DUCT 1 19 08543 8 ROUND ADAPTER 1 20 18509 LOWER PLENUM PLATE 1 21 18508 UPPER PLENUM PLATE 1...

Отзывы: