13. OPERATION (
CONT
’
D
)
- 16 -
HC0052
A
B
C
D
E
F
G
A)
Blower Delay/Control Lock button
B)
Blower low speed button
— LinkLogic
®
Erase Link button
C)
Blower medium-low speed button
— LinkLogic
®
Master Link Mode button
D)
Blower medium-high speed button
— LinkLogic
®
Auto Link Mode button
E)
Blower high speed button
— LinkLogic
®
Activate/Exit Link Mode button
F)
Master ON/OFF button
G)
Light/Backlighting Color button
A. D
ELAY
B
UTTON
/C
ONTROL
L
OCK
(D
OUBLE
F
UNCTION
B
UTTON
):
i. When a blower speed is selected, press this button to activate the delay function. The delay
button will light to its high intensity, then to its mid intensity to indicate this function is activated;
the selected blower speed button will alternate every 2 seconds from its high intensity to its
mid intensity. The blower will continue to operate for 5 minutes and will stop automatically.
Selecting another speed while the delay function is activated will not deactivate the function
or reset the timer. To cancel the delay function, press the delay button once again or the
selected speed button which last case will also turn the blower off.
ii. When blower is off, it is possible to lock the control interface in order to clean the glass panel.
To lock the control interface: Press and hold the button for 3 seconds. The button will light to
its high intensity and flash three times, it will then stay on its mid intensity to indicate that the
control interface is locked.
To unlock the control interface: Press and hold the button for 3 seconds. The button will light
to its high intensity and flash 3 times, it will then fade out to its low intensity to indicate that
the control interface is unlocked.
B-E. S
PEED
S
ELECTION
B
UTTONS
:
Press the button corresponding to the desired blower speed (from
1
for low speed to
4
for high
speed). The chosen speed button will light to its high intensity then fade to its mid intensity. To
turn off the blower, press once more on the corresponding blower speed button; the button light
will fade to its low intensity.
NOTE: When blower is off, pressing on blower speed
1
button will cause the blower to start on
second speed for a very short lapse of time, and then resume on speed
1
.
F. M
ASTER
ON/OFF:
When blower and lights are off, press this button to turn the hood on to the last memorized
speed level and light intensity. If there are no memorized speed level and light intensity, speed
will be set at level
1
and light intensity at
4
. To turn off the blower and the light simultaneously,
press this button once.
H
EAT
S
ENTRY
™:
The hood is equipped with a HEAT SENTRY thermostat. When blower is ON at
any speed and excessive heat is detected above the cooking surface, it sets the
blower on third speed. The third speed button backlight will blink quickly to indicate
that the Heat Sentry has been activated. When the temperature level drops to normal,
the blower will return to its original setting.
NOTE: When Heat Sentry is activated, the communication coming from the
LinkLogic device is disabled and the “DELAY OFF” function is inactivated.
The Heat Sentry can take control of the blower when excessive heat is detected
above the cooking surface. If this situation occurs and you must stop the blower,
press on the third speed button or on the master ON/OFF button.
WARNING
!