4. CONTROLS
(
CONT
’
D
)
4.5 E
LECTRICAL
C
ONNECTION
TO
M
AIN
C
ONTROLS
For more convenience, these units can also be controlled using an optional main wall control.
NOTES: 1. The integrated control must be turned OFF to use an optional main control.
2. If an optional auxiliary control is used, it’s activation will override the optional main control.
WARNING
!
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical
shock or damage of the wall control or electronic module inside the unit.
CAUTION
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit
between themselves or by touching any other components on the wall control. Avoid poor wiring connections. To
reduce electrical interference (noise) potential, do not run wall control wiring next to control contactors or near
light dimming circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.
Use the terminal connector included in the installation kit to perform the electrical connection for
main and optional wall controls. Check if all wires are correctly inserted in their corresponding holes
in the terminal block. (A wire is correctly inserted when its orange receptacle is lower than another
one without wire. On picture at right, wire
A
is correctly inserted, but wire
B
is not.)
4.5.1 E
LECTRICAL
C
ONNECTION
TO
A
LTITUDE
(AVS E15 ECM ERV
AND
AVS E15 ECM HRV
UNITS
ONLY
)
OR
P
LATINUM
(90H-V ECM ERV
AND
90H-V ECM HRV
UNITS
ONLY
)
M
AIN
W
ALL
C
ONTROL
NO C NC I OC OL Y R G B
VE0181
SMART
SET
MODE
PREF
4.5.2 E
LECTRICAL
C
ONNECTION
TO
D
ECO
-T
OUCH
M
AIN
W
ALL
C
ONTROL
(A
LL
UNITS
)
NO C NC I OC OL Y R G B
VE0250
4.5.3 E
LECTRICAL
C
ONNECTION
TO
L
ITE
-T
OUCH
C
ONSTRUCTO
(AVS E15 HRV
AND
AVS E10 HRV
UNITS
ONLY
)
OR
L
ITE
-T
OUCH
B
RONZE
(90H-V+
AND
60H-V+
UNITS
ONLY
)
M
AIN
W
ALL
C
ONTROL
NO C NC I OC OL Y R G B
B
G
OC
MAIN WALL CONTROL
LITE-TOUCH CONSTRUCTO
or
LITE-TOUCH BRONZE
REAR VIEW
G B
Y
VE0186A
4.5.4 E
LECTRICAL
C
ONNECTION
TO
C
ONSTRUCTO
(AVS E15 HRV
AND
AVS E10 HRV
UNITS
ONLY
)
OR
B
RONZE
(90H-V+
AND
60H-V+
UNITS
ONLY
) M
AIN
W
ALL
C
ONTROL
NO C NC I OC OL Y R G B
VE0187
VE0272
A
B