Instructions:
1-
Determine the location of the control
The wall control must be installed in a central location on the main floor. Typical locations for this control are kitchens, main hallways
and family rooms.
2-
Remove the buttons and the cover plate of the control.
(See Figure 16).
3-
Install the wall control at approximately 60 inches (1.5 m) from the ground floor of
the house.
Use the template provided in the control box to position the wire hole and the
screw holes.
Use the screws and the plastic shields provided in the installation kit to secure the
control to the wall.
20
5.7 Connecting the Drain
5.0 Installation
(cont’d)
Make a water trap loop in the tube to prevent the unit from drawing unpleasant
odors from the drain source. Make sure this loop is situated BELOW the “T”
as shown. This will prevent water from being drawn back up into the unit in
case of negative pressure.
Run the tubing to the floor drain or to an alternative drain pipe or pail. Be sure
there is a slight slope for the run-off.
12"(
3
05 mm)
VO0004
VO000
3
VO0006
VO0005
To drain
Cut 2 sections of plastic tubing, about
12” (305 mm) long and attach them to
each drain fitting.
Attach the 2 plastic drain fittings to the
unit using the gaskets, washers and
nuts as shown.
Join these 2 short sections to the“T”
junction and main tube as shown.
6.1 Installation
VC0024
6.0 Installation of the Main Control
CAUTION
Never install more than one main control per unit.
Figure 16
NOTE: Since this manual is not dedicated to a specific trade mark, this section will cover only the broad lines of main control installation.
For more information about specific features of the main control you will install, refer to the specification sheet of this product.
The following illustrations are typical ones, the main control you will install may look and be different.