background image

EN

MANUALE 

TECNICO

TECHNICAL 

MANUAL

ONDA VF

IT

Содержание ONDA VF

Страница 1: ...EN MANUALE TECNICO TECHNICAL MANUAL ONDA VF IT ...

Страница 2: ...iva UE 2017 164 in relazione al TLV STEL Threshold Limit Value short term exposure limit per gli analiti non considerati nella suddetta normativa si fa riferimento ai limiti TLV STEL della ACGIH I risultati delle analisi rapportati ai valori limite sono visibili in tabella Dai risultati ottenuti appare evidente come i vapori generati dal processo di combustione del fumogeno in questione in un ambi...

Страница 3: ...ile 12V 1 2Ah ermetica al piombo classe infiammabilità V2 minima Prestazione fumogeno 100m3 in 30 secondi Grado di protezione IP44 Temperatura di funzionamento da 0 a 45 C Dimensioni L x H x P 320 x 236 x 93 peso 2 600g CONNETTORI J5 COLLEGAMENTO BATTERIA J4 CONNETTORE FUMOGENO CAPSULA J7 J8 CONNETTORI LED DESTRO E SINISTRO LED DL1 LED SEGNALAZIONE ANOMALIE DL2 LED ALIMENTAZIONE RICARICA DL3 LED A...

Страница 4: ...ANO IMPOSSIBILITATI AD EVACUARE IL LOCALE IN CASO DI EROGAZIONE DEL FUMO Durante l erogazione del fumo è possibile il rilascio nel locale di qualche grammo di polvere Si rende noto che tale polvere non danneggia cose né persone FISSAGGIO A MURO E PASSAGGIO CAVI COLLEGAMENTO MORSETTIERA 220V ATTENZIONE PROCEDERE AI CABLAGGI MA ALIMENTARE LA ONDA VF SOLO DOPO AVER COLLEGATO LA BATTERIA Il collegamen...

Страница 5: ... secondo ingresso ALLARME consente il collegamento di un dispositivo di rilevazione es sensore infrarosso da installare nello stesso ambiente per confermare il segnale di pre allarme e quindi far partire il fumogeno Il terzo ingresso BLOCCO RAPINA è di default un ingresso di blocco per gli ingressi di pre allarme e allarme può essere ad esempio collegato allo stato impianto di una centrale dall al...

Страница 6: ...ENO INGRESSI PRE ALLARME E ALLARME L ingresso PRE ALLARME mette in allerta la scheda tale ingresso può essere collegato ad un uscita di allarme di una centrale e programmato come normalmente chiuso NC o normalmente aperto NA e positivo o negativo tramite DIP SWITCH 4 e 5 La scheda attende la conferma dell ingresso ALLARME che può essere collegato ad un sensore infrarosso un contatto magnetico o co...

Страница 7: ...RM ANOMALY LIGHT BLOCK ALARM INGRESSO BLOCCO RAPINA L ingresso BLOCCO RAPINA se impostato come BLOCCO inibisce gli ingressi PRE ALLARME e ALLARME mantenendo bloccata la partenza del fumogeno anche se è in corso una temporizzazione Tale ingresso può essere collegato ad un uscita di stato impianto della centrale d allarme per garantire il blocco del fumogeno in caso di anomalia dell impianto Se impo...

Страница 8: ... LD 81 2008 in transposition to the EU Directive 2017 164 with reference to TLV STEL Threshold Limit Value short term exposure limit for the analytes not considered in the norm written above limits TLV STEL of ACGIH are applied The following chart shows the values measured with respect to the limit of reference The results above highlight that the smoke generated by burning process of the smoke ca...

Страница 9: ... switch Compatible with 12V 1 2Ah sealed lead acid battery flammability class V2 minimum Smoke performance 100m3 in 30 seconds Protection level IP44 Operating temperature 0 C 45 C Size W x H x D 320 x 236 x 93 Weight 2600gr CONNECTORS J5 BATTERY CONNECTION J4 SMOKE CONNECTION CAPSULE J7 J8 RIGHT LEFT LED CONNECTION LED DL1 ANOMALY SIGNALING LED DL2 POWER SUPPLY RECHARGE LED DL3 ACTIVATION LED FOR ...

Страница 10: ...UPIED BY PEOPLE OR ANIMALS UNABLE TO EVACUATE During discharge the smoke could emit a few grams of dust However this light dust do not damage things nor people WALL FIXING AND CABLE PASSING 220V TERMINAL BLOCK CONNECTION ATTENTION PROCEED TO THE NECESSARY WIRING BUT GIVE ELECTRICAL SUPPLY TO ONDA VF ONLY AFTER BATTERY CONNECTION Mains connection must respect the installation norms in force in the ...

Страница 11: ...he connection to a detection device for example an infrared sensor to be installed in the same room to confirm pre alarm signal and consequently to activate the smoke system The third input BLOCK ANTI ROBBERY is by default a block input for alarm pre alarm inputs It can be connected for example to the system status of an alarm control panel or fire panel By moving dip switch 7 in ON block anti rob...

Страница 12: ...WITCH MODE BUTTON MODE WITH DIMMERING CONDITIONS FOR SMOKE SYSTEM ACTIVATION PRE ALARM AND ALARM INPUTS PRE ALARM input sets the board to warning mode this input can be connected to an alarm output of a control panel and can be set to normally closed NC or normally open NO and positive or negative through DIP SWITCHES 4 and 5 The board waits for the confirmation from ALARM input which can be conne...

Страница 13: ...to your supplier 18 YEARS NOTE BLOCK ANTI ROBBERY INPUT If set as BLOCK BLOCK ANTI ROBBERY input inhibits PRE ALARM and ALARM inputs by keeping smoke discharge blocked even if a timing is running This input can be connected to a system status output of the control panel to ensure smoke discharge blocking in case of anomaly of the system If set as ANTI ROBBERY this input has priority over ALARM and...

Страница 14: ...14 MANUALE TECNICO TECHNICAL MANUAL ...

Страница 15: ...NOTE 15 ...

Страница 16: ...gale e operativa Via del Lavoro 10 30030 Salzano VE Italy Tel 39 041 5740374 Fax 39 041 5740388 info venitem com www venitem com UNI EN ISO 14001 UNI EN ISO 9001 AZIENDA CERTIFICATA MA SF ONVF 00 00 1518169958 ...

Отзывы: