Use the unit only for the specified purpose.

Do not use the unit on multiple sockets. Do not plug the power plug of this appliance into a socket with other appliances.

Avoid shaking or dropping the unit during use or transport. Protect the unit from falls and shocks.

Keep the unit and cuffs away from heat sources (e.g. radiators, cigarettes or direct sunlight) and use only at the intended operating 

temperature. Use outside the intended operating temperature could cause damage, discolouration and deformation to the cuffs.

Remain seated during use. With the cuffs on, keep your legs and arms still. Do not run with the cuffs on

Do not use running water, oil, petrol, alcohol or other chemicals to clean the cuffs and the unit to avoid shortening the product life. 

Only use a damp cloth to clean the cuff and textile cleaner if it is very dirty. To clean the unit, please use a dry cloth.

Do not use the device naked. Wear underwear or trousers during use.

Do not open the cuffs during use to avoid damaging the cuffs.

When disposing of the device, cuffs, remote control battery or packaging, please follow local disposal guidelines and avoid environ-

mental pollution.

lf the pressure sensor is damaged, loose or fails, the unit may malfunction. Please

contact the manufacturer for inspection and maintenance.

Keep the unit out of reach of pets.

The unit should be placed so that the plug can be easily connected and disconnected from the power supply.

Take care not to place heavy objects on cuffs, hoses and other accessories and not to twist or bend them, as this may cause damage to 

the pressure sensor.

lf the unit is not used for a long time or is used at low temperatures, the unit may not be usable. Allow the unit to inflate any cuff 3 to 4 

times to the highest pressure level before use

WORKING PRINCIPLE

Compression therapy using compressed air is a therapeutic technique used in medical equipment that includes an air pump and inflatable 

cuffs (gloves, boots, jacket, sleeves). During application, an inflatable cuff envelops the limb to be treated. The cuff is connected to the 

pump via several pressure pipes. When the pump is activated, it fills the cuff's air chambers, in order to exert pressure on the tissues in 

the limb, thereby displacing liquids such as blood and lymph from the pressurized area. A short time later, the pressure is reduced, 

allowing increased blood flow back to the limb.

EN

Содержание 4

Страница 1: ...OPERATING INSTRUCTIONS ENGLISH VENEN ENGEL 4...

Страница 2: ...es or if you have suggestions please do not hesitate to contact us We are also happy to help you with any complications that develop during or after using the product Telephone 49 0 666 17 48 91 05 Wh...

Страница 3: ...metic use the system provides drainage of loosened fat cells and debris through its massage from the feet towards the upper body INFORMATION INDICATIONS Prevention of Deep vein thrombosis DVT Chronic...

Страница 4: ...and only by specialists authorised by the manufacturer In addition there is a risk of loss of warranty In case of general discomfort or pain during use please discontinue use immediately Do not allow...

Страница 5: ...ow local disposal guidelines and avoid environ mental pollution lf the pressure sensor is damaged loose or fails the unit may malfunction Please contact the manufacturer for inspection and maintenance...

Страница 6: ...ms or those with high humidity such as in saunas or bathrooms Tightening Leg cuffs To prevent contamination we recommend wearing leggings or sweatpants when using the device Empty your pockets before...

Страница 7: ...mum of 5 minutes the first time and then increase incrementally 2 3 Remote Control Batteries Before the initial use Remove the battery protection and insert the battery Type CR2032 Diameter 20mm Heigh...

Страница 8: ...GE The leg cuff air chambers inflate one by one This creates an optimal gliding pressure wave massage for a relaxed feeling in both legs Duration and pressure can be adjusted even during the massage M...

Страница 9: ...ing you can also use a gentle textile cleaner Before cleaning the cuffs remove the hose plugs and always allow the cuffs to dry thoroughly When used by different people we recommend disinfection of th...

Страница 10: ...he fuse is undamaged C lf the fuse is intact screw the fuse holder with the fuse back into the device completely lf the fuse is damaged replace the fuse with a commercially available fine fuse TR 3 15...

Страница 11: ...curing the de vice during transport and it can subsequently be disposed of THE CUFFS ARE INFLATING IN THE WRONG ORDER Make sure that the multi plug is correctly inserted into the device There is a sma...

Страница 12: ...OP PUTTING ON THE ARM CUFF Step 1 Step 2 Step 4 Step 3 Velcro the strap to the back of the cuff Pull the cuff onto your arm and make sure the end is sitting on your shoulder Run the strap under your o...

Страница 13: ...ispose of the product via your general household waste disposal Alternatively we are happy to take care of the disposal of your old Venen Engel free of charge Just send it to Wellcosan GmbH Bellinger...

Страница 14: ...x28x15 cm Protection Class II Temperature range use and storage 10 40 C Humidity relative use and storage 30 85 Programmes 1 Number of chambers 4 Weight ca 3 kg Power output 30 W Mains Frequency 50 60...

Страница 15: ...PACKAGE CONTENTS Control unit Multi Plug air hose set Compression boots The scope of delivery of the boots depends on the set purchased Power plug 37 EN...

Страница 16: ...ency Directive 93 42 EEC Serial number Lot number Attention Please pay attention to this important information regarding health risks European plenipotentiary Operate only in temperature range 10 C to...

Страница 17: ...rmal operation in the configuration in which it will be used Guidance and manufacturer s declaration electromagnetic emission The device is intended for use in the electromagnetic environment specifie...

Страница 18: ...ential mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 9...

Страница 19: ...romagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MH...

Страница 20: ...tion bl 2 0 3 28 1970 GSM 1900 DECT LTE Band 1 3 4 25 UMTS 217Hz 2450 2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation bl 217Hz 2 0 3 28 5240 5500 5785 5100 5800 WLAN 802 11...

Страница 21: ...l Maximum power W Distance m immunity Test Level V m 385 380 390 TETRA400 Pulse modulation bl 18Hz 1 8 0 3 27 450 430 470 GMRS460 FRS 460 FM 1 SkHz deviation kHz sine 2 0 3 28 710 745 780 704 787 LTE...

Страница 22: ...roper operation externally applied force or modifications and repair work performed by third parties e g defects caused by incorrectly rated or short circuited fuses or defects attributable to normal...