ALL  ELECTRICAL  CONNECTIONS  SHALL  BE  DONE  ACCORDING  TO  EN  60204-1 
BY TRAINNED AND AUTHORIZED PERSONNEL. 

 

 

SWITCH  THE  ENERGY  SUPPLY  OFF  BEFORE  YOU  BRING  ABOUT  THE 
ELECTRICAL  CONNECTION  OF  THE  FAN.  MAKE  SURE  THAT  THE  ENERGY 
SUPPLY  CANNOT  BE  SWITCHED  ON  AGAIN  PREMATURELY.  THE  ELECTRICAL 
CONNECTION MAY ONLY BE CARRIED OUT BY TRAINED PERSONNEL. 

 

THE  ELECTRICAL  CONNECTION  IS  TO  BE  DONE  ACCORDING  TO  VALID 
DIRECTIVES  AND  ONLY  BY  A  QUALIFIED  FITTER  WITH  MATCHING  SAFETY 
DEVICES FOR THE PROTECTION OF THE MOTOR. 

 

ALL COMPONENTS SHOULD BE EARTHED. DEVICE EARTH CONNECTION MUST 
BE  DONE  ON  TOP  OF  THE  CONNECTOR  IN  JUNCTION  BOX  and  FROM 
GROUNDING SCREW WITHIN BODY. 

Содержание VAX-EX

Страница 1: ...MAINTENANCE USER MANUAL EXPROOF AXIAL FANS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MAN SA T RK YE Tel 0090 236 332 5070 Fax 0090 236 332 5030 www venco com tr venco...

Страница 2: ...s a workbench or a storage area VENCO VAX EX Axial Type Exproof Fans can only be operated in conditions of intended design and technical specifications DEVICES TO BE USED IN DANGEROUS ENVIRONMENTS ARE...

Страница 3: ...1 area is classified as a place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas vapour or mist is likely to occur in normal operation occa...

Страница 4: ...gle impellers Aerodynamic profile impellers allow high efficiency and low noise Die cast aluminum alloy fan hubs Optimum capacity obtained hub combinations besides adjustable blade combination IP 67 t...

Страница 5: ...ing the exproof certified coupling Ex d protection type T4 temperature class from the junction box A wiring diagram is applied on the inside of the junction box or separately enclosed Electrical insta...

Страница 6: ...SUPPLY CANNOT BE SWITCHED ON AGAIN PREMATURELY THE ELECTRICAL CONNECTION MAY ONLY BE CARRIED OUT BY TRAINED PERSONNEL THE ELECTRICAL CONNECTION IS TO BE DONE ACCORDING TO VALID DIRECTIVES AND ONLY BY...

Страница 7: ...ould be bridged to the duct connection 7 HANDLING STORAGE The fans are delivered on wooden pallets wrapped in plastic stretch Transport the fan to the place of assembly in its original packaging Durin...

Страница 8: ...the OFF position Also DO NOT START sign should be placed on the control panel that will consistently stand Check that the electrical connections to the unit are secure Check that the voltage applied...

Страница 9: ...2019 02 8 8 ANNEX 11 1 Annex 1 Electrical Wiring Diagrams Device connection 4KW and above Device connection under 4KW...

Отзывы: