4.  TECHNICAL SPECIFICATIONS 

     VENCO VAX-EX Type Exproof Axial Fans; 

Certificate Number : 

IEP 17 ATEX 0539 

Ex Code: 

 

 

 

  Full size from 

Ø 

500 mm to 

Ø 

1400 mm diameter 

  1000 

m³/h – 150.000 m³/h air flow 

  Hot deep galvanized sheet metal casing 

  Cast aluminum adjustable blade angle impellers 

  Aerodynamic profile impellers allow high efficiency and low noise 

  Die cast aluminum alloy fan hubs 

  Optimum capacity obtained hub combinations besides adjustable blade combination 

  IP 67 terminal box has exproof certificate is carried out of the casing 

  Electrical motors with IP 55 and Ex d IIB T4 class 

  380 V, 3 phase, 50 Hz 

  Operating temperature between -20

°

C and 40

°

  230 V, 1 phase, 50 Hz and 400 V, 3 phase, 50 Hz 

  Operating temperature 300

°

C for 2 hours 

 

 

Содержание VAX-EX

Страница 1: ...MAINTENANCE USER MANUAL EXPROOF AXIAL FANS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MAN SA T RK YE Tel 0090 236 332 5070 Fax 0090 236 332 5030 www venco com tr venco...

Страница 2: ...s a workbench or a storage area VENCO VAX EX Axial Type Exproof Fans can only be operated in conditions of intended design and technical specifications DEVICES TO BE USED IN DANGEROUS ENVIRONMENTS ARE...

Страница 3: ...1 area is classified as a place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas vapour or mist is likely to occur in normal operation occa...

Страница 4: ...gle impellers Aerodynamic profile impellers allow high efficiency and low noise Die cast aluminum alloy fan hubs Optimum capacity obtained hub combinations besides adjustable blade combination IP 67 t...

Страница 5: ...ing the exproof certified coupling Ex d protection type T4 temperature class from the junction box A wiring diagram is applied on the inside of the junction box or separately enclosed Electrical insta...

Страница 6: ...SUPPLY CANNOT BE SWITCHED ON AGAIN PREMATURELY THE ELECTRICAL CONNECTION MAY ONLY BE CARRIED OUT BY TRAINED PERSONNEL THE ELECTRICAL CONNECTION IS TO BE DONE ACCORDING TO VALID DIRECTIVES AND ONLY BY...

Страница 7: ...ould be bridged to the duct connection 7 HANDLING STORAGE The fans are delivered on wooden pallets wrapped in plastic stretch Transport the fan to the place of assembly in its original packaging Durin...

Страница 8: ...the OFF position Also DO NOT START sign should be placed on the control panel that will consistently stand Check that the electrical connections to the unit are secure Check that the voltage applied...

Страница 9: ...2019 02 8 8 ANNEX 11 1 Annex 1 Electrical Wiring Diagrams Device connection 4KW and above Device connection under 4KW...

Отзывы: