Symptom 

Cause of Failure 

Recommendation 

The Switch not working and 
LED off 

1.  The Switch is not 

connect to the Main 
power 

2.  The Switch break 

down 

1.  Check power connections 
2. Don’t open up the Switch and 

send it for repair. 

The Switch LED 
illuminating, but cannot 
control the ON/OFF 
Switch of the load attached 

Check if the load connect 
into the Switch has its 
own ON/OFF switch 

Set the ON/OFF switch of the load 
attached to ON 

The Switch LED 
illuminating, but the 
Detector cannot control 
the Switch 

1. Not carry out 

association 

2. Same frequency 

interference 

1. Carry out association 
2. Wait for a while to re-try 

LED keep flashing, but 
cannot control 

Overload occurs 

Remove the load attached or check 
max. load cannot exceed 
7.5A(Resistive load)

 

 

Specification 
 

Operating Voltage

 

100 ~240VAC 

Maximum Load

 

6.5A(230Vac/120Vac) (Resistive load) 

Range 

Minimum 30 m in door 100m outdoor    line of sight 

Operating Temperature  0°C ~ 40°C 
Frequency Range 

DS-100-1: 868.40MHz; 869.85MHz(EU) / 
DS-100-2: 908.40MHz; 916.00MHz(USA/Canada) / 
DS-100-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP) 

** Specifications are subject to change and improvement without notice.                           

 

 

 

                                                         

   

 

 

Warning: 

1. Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating 

 

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling. 

Company of License Holder

Philio Technology Corporation 

Address of License Holder

8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., 

New Taipei City 24257,Taiwan(R.O.C) 

 

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference 

in a residential installation.   

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference to 

radio communications.   

However, there is no guarantee that interference will not occur in a particular installation.   

If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one of the following measures:

 

•  

Reorient or relocate the receiving antenna.

 

•  

Increase the separation between the equipment and receiver.

 

•  

Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

 

Содержание DS-100

Страница 1: ...etecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly However disconnect and re connect the Module will reset its overload condition...

Страница 2: ...Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes pe...

Страница 3: ...port ON when relay 2 ON Report OFF when relay 2 OFF Configuration parameter 3 3 default Report ON when either relay 1 ON or relay 2 ON Report OFF when both relay 1 and relay 2 OFF Basic Get Command Co...

Страница 4: ...3 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5...

Страница 5: ...it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Me...

Страница 6: ...int set to 3 DS 100 will reply ON 0xFF when either Relay 1 or Relay2 is ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Below is an example show a source endpoint 5 send a Get command to DS 10...

Страница 7: ...value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x01 Switch_Binary_Set 0x01 Parameter 1...

Страница 8: ...l this value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x05 Meter_Reset 0x05 2 3 5 METER_GET...

Страница 9: ...rce End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit A...

Страница 10: ...Scale V 0x04 DS 100 AC load Voltage report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0...

Страница 11: ...02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x4A Precision 2 Scale Bit1Bit0 0x01 Size 2 Parameter 3 0x00 Current 0x002B 0 43A Parameter 4 0x2B 2 3 5 5 Get power factor...

Страница 12: ...0 7 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 8 Auto off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off command mode 1 0 3 0 0 Switc...

Страница 13: ...same position correspond to same state of relay1 and relay2 if the DS 100 relay change the state because of receiving Z Wave RF command it may need two times of change switch on to off or switch off...

Страница 14: ...Endpoint3 is dynamic 4 Protection Command Classes DS 100 supports Protection Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect t...

Страница 15: ...environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collect...

Страница 16: ...armful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by...

Отзывы: