13
3-3-1 Selected Relay1:
Only relay1 can be controlled and report.
3-3-2 Selected Relay 2:
Only relay2 can be controlled and report.
3-3-3 Selected Relay1 and Relay2
:
:
:
:
Default select is 3
Both relay1 and relay2 can be controlled and report.
Set command
Relay state
Basic_Set or Binary_Switch_Set ON
Both Relay1 and Relay2 ON.
Basic_Set or Binary_Switch_Set OFF
Both Relay1 and Relay2 OFF.
Get command
Relay state
Report to command sender
Basic_Get or Binary_Switch_Get
Either relay1 ON
or relay2 ON
ON
Basic_Get or Binary_Switch_Get
Both relay1 OFF
and relay2
OFF
OFF
Get command
parameter
Report to command sender
Meter_Get
KWh
Relay1 KWh1+Relay2 KWh2
Meter_Get
Watt
Relay1 W1+Relay2 W2
Meter_Get
Voltage
Relay1 and Relay2 are the same
voltage
Meter_Get
Current
Relay1
I
1+Relay2
I
2
Meter_Get
Power factor PF
Relay1
3-4 Edge and Pulse mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle
mode, default value is Edge mode.
3-4-1 Edge mode: this mode is suitable for the bi stable wall switch that has
indicator point on the switch, and the same position correspond to same
state of relay1 and relay2. if the DS-100 relay change the state because of
receiving Z-Wave RF command, it may need two times of change (switch on
to off or switch off to on) to let relay back to the correspond state.
3-4-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap
the state of Relay1 or Relay2.
3-4-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch,
every time when change the state of the wall switch will also swap the state
of Relay1 or Relay2.
3-5 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 750, when the load current of Relay1 or Relay2 over this value,
DS-100 will send current meter report to the node of correspond Group, the
Range of the setting value is from 10 to 750, and the default value is 750.
3-6 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 or
Relay2 over this value, DS-100 will send KWh Meter Report command to the
node of correspond Group, minimum value is 1KWh and default value is 10000
kWh.
3-7 Restore switch state mode