Vemmio DS-100 Скачать руководство пользователя страница 1

 
 

DS-100 

double switch

 

             

 

 

Fig 1. Assembling 

 

This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus

TM

 

enabled device and is fully compatible with any Z-Wave

TM

 enabled network. 

Z-Wave Plus

TM

 enabled devices displaying the Z-Wave Plus

TM

 logo can also be 

used with it regardless of the manufacturer, and can also be used in other 

manufacturer’s    Z-Wave

TM

 enabled networks. Mini size design let the module 

can easily hide itself into the wall box and that will be good for the house 
decoration.   
There are many kind of application by using the module to switch AC power On 
and Off, one main application is the light control. The new smart relay calibration 
technology can reduce the inrush current caused by the load and let the module 
work perfectly with many kind of light like incandescent, fluorescent and LED 
light.     
 

This in-wall switch module is able to detect Instant power wattage and overload 

current (7.5A with resistive load) of connected light or appliances. When 

detecting overload state, the Module will be disabled and its On/Off button will 

be lockout of which LED will flash quickly. However, disconnect and re-connect 

the Module will reset its overload condition to normal status.

 

 

 

Adding to Z-Wave

TM

 Network

 

 
In  the  front  casing,  there  is  an  on/off  button  with  LED  indicator  below  which  is 
used  to  toggle  switch  on  and  off  or  carry  out  inclusion,  exclusion,  reset  or 
association. When  first  power  is  applied,  its  LED  flashes  on  and  off  alternately 
and repeatedly at 0.5 second intervals. It implies that it has not been assigned a 
node ID and start auto inclusion.   
 
Auto Inclusion 
 
The function of auto inclusion will be executed as long as the in wall switch does 
not have Node ID and just connect the switch to main power. 
 
Note:
 Auto inclusion timeout is 2 minute during which the node information of 
explorer frame will be emitted once every several seconds. Unlike “inclusion” 
function as shown in the table below, the execution of auto inclusion is free from 
pressing the On/Off button on the Switch. 
 
 
The table below lists an operation summary of basic Z-Wave functions. Please 
refer to the instructions for your Z-Wave

TM

 Certificated Primary Controller to 

Содержание DS-100

Страница 1: ...etecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly However disconnect and re connect the Module will reset its overload condition...

Страница 2: ...Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes pe...

Страница 3: ...port ON when relay 2 ON Report OFF when relay 2 OFF Configuration parameter 3 3 default Report ON when either relay 1 ON or relay 2 ON Report OFF when both relay 1 and relay 2 OFF Basic Get Command Co...

Страница 4: ...3 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5...

Страница 5: ...it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Me...

Страница 6: ...int set to 3 DS 100 will reply ON 0xFF when either Relay 1 or Relay2 is ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Below is an example show a source endpoint 5 send a Get command to DS 10...

Страница 7: ...value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x01 Switch_Binary_Set 0x01 Parameter 1...

Страница 8: ...l this value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x05 Meter_Reset 0x05 2 3 5 METER_GET...

Страница 9: ...rce End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit A...

Страница 10: ...Scale V 0x04 DS 100 AC load Voltage report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0...

Страница 11: ...02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x4A Precision 2 Scale Bit1Bit0 0x01 Size 2 Parameter 3 0x00 Current 0x002B 0 43A Parameter 4 0x2B 2 3 5 5 Get power factor...

Страница 12: ...0 7 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 8 Auto off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off command mode 1 0 3 0 0 Switc...

Страница 13: ...same position correspond to same state of relay1 and relay2 if the DS 100 relay change the state because of receiving Z Wave RF command it may need two times of change switch on to off or switch off...

Страница 14: ...Endpoint3 is dynamic 4 Protection Command Classes DS 100 supports Protection Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect t...

Страница 15: ...environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collect...

Страница 16: ...armful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by...

Отзывы: