Vemmio DS-100 Скачать руководство пользователя страница 3

WWW.VEMMIO.COM

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command = 0x02

(Meter_Report = 0x02)

Parameter 1 = 0x21

(Scale Bit2 = 0, Rate Type = 
0x01,Meter Type=0x01)

Parameter 2 = 0x34

(Precision = 1, Scale Bit1Bit0 
= 0x02, Size = 4)

Parameter 3 = 0x00

Instant Power Consumption = 
0x000003EA = 100.2W

Parameter 4 = 0x00
Parameter 5 = 0x03
Parameter 6 = 0xEA

2-3-5-3 Get load voltage V from endpoint:

Meter_GET example:

Source End Point = 0x05

(this is the endpoint of com-
mand inquirer, here we as-
sume endpoint is 5, if the
inquirer doesn’t support multi 
Channel this value will be 0)

(Bit Destination End 
Point = 0x03)

(Bit Address =0; Destination 
End Point range1~3)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x01

(Meter_Get = 0x01)

Parameter 1 = 0x20

(Scale = V = 0x04)

DOUBLE SWITCH AC load Voltage report example:

Source End Point = 0x03

(Meter report = Endpoint3)

(Bit Destination End 
Point = 0x05)

(Bit Address =0 ; Destination 
End Point = command in-
quirer’s Endpoint value)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x02

(Meter_Report = 0x02)

Parameter 1 = 0xA1

(Scale Bit2 = 1, Rate Type = 
0x01, Meter Type=0x01)

Parameter 2 = 0x22

(Precision = 1, Scale Bit1Bit0 
= 0x00, Size = 2)

Parameter 3 = 0x09

Voltage = 0x0910 = 232.0V

Parameter 4 = 0x10

2-3-5-4 Get load current I from endpoint:

Meter_GET example:

Source End Point = 0x05

(this is the endpoint of 
command inquirer, here we 
assume endpoint is 5, if the 
inquirer doesn’t support multi 
Channel this value will be 0)

(Bit A Destination 
End Point = 0x03)

(Bit Address =0;Destination 
End Point range1~3)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x01

(Meter_Get = 0x01)

Parameter 1 = 0x28

(Scale = A = 0x05)

DOUBLE SWITCH AC load current (I) example:

Source End Point = 0x03

(Meter report = Endpoint3)

(Bit Destination End 
Point = 0x05)

(Bit Address =0;Destination 
End Point = command in-
quirer’s Endpoint value)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x02

(Meter_Report = 0x02)

Parameter 1 = 0xA1

(Scale Bit2 = 1, Rate Type = 
0x01, Meter Type=0x01)

Parameter 2 = 0x4A

(Precision = 2, Scale Bit1Bit0 
= 0x01, Size = 2)

Parameter 3 = 0x00

Current = 0x002B= 0.043A

Parameter 4 = 0x2B

Current = 0x002B= 0.043A

2-3-5-5 Get power factor PF from endpoint

Meter_GET example:

Source End Point = 0x05

(this is the endpoint of 
command inquirer, here we 
assume endpoint is 5, if the 
inquirer doesn’t support multi 
Channel thiS value will be 0)

(Bit Destination End 
Point = 0x03)

(Bit Address =0;Destination 
End Point range 1-3)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x01

(Meter_Get = 0x01)

Parameter 1 = 0x30

(Scale = PF = 0x06)

DOUBLE SWITCH power factor report example:

Source End Point = 0x03

(Meter report = Endpoint 3)

(Bit Destination End 
Point = 0x05)

(Bit Address =0;Destination 
End Point = command in-
quirer’s Endpoint value)

Command Class = 0x32

(Command_Class_Meter_V3 
= 0x32)

Command =0x02

(Meter_Report = 0x02)

Parameter 1 = 0xA1

(Scale Bit2 = 1, Rate Type = 
0x01,Meter Type=0x01)

Parameter 2 = 0x51

(Precision = 2, Scale Bit1Bit0 
= 0x10, Size =1)

Parameter 3 = 0x63

Power Factor = 0x63 = 0.99

3. Z – Wave’s Configuration

Configuration 
Parameter

Size (Byte)

Unit

Default

Function

Value

Description

1 Watt Me-

ter Report 
Period

2 0x01-

0x7FFF

5s

720 720*5s=3600s=1 

hour

2 KWH Me-

ter Report 
Period

2 0x01-

0x7FFF

10min 6

6*10min= 1 hour

3 Selected 

Relay

1 1-3

3

1:Relay 1
2:Relay 2
3:Relay 1 & 
Relay 2

4 Edge or 

Pulse mode 
or Edge-
Toggle 
mode

1 1-3

1

1:Edge mode
2:Pulse mode
3:Edge-Toggle 
mode

5 Threshold 

of current 
for Load 
Caution

2 10-750 0.01A 750 750*0.01A = 7.5A

6 Threshold 

of KWH 
for Load 
Caution

2 1- 

10000

1KWh 10 

00 
0

7 Restore 

switch 
state 
mode

1 0-2

1

0 Swith off
1 Last switch 
state 
2 Switch on

8 Auto off 

timer

2 0-0x 

7FFF

1s

0

0 Disable auto off 
function
1 0x7FFF 1s- 
32767s

9 RF off 

command 
mode

1 0-3

0

0 Switch off
1 Ignore
2 Switch toggle
3 Switch on

10 Existance 

of End-
point 3

1 1-2

1

1 Endpoint 3 exist 
2 No Enpoint 3

3-1 Watt Meter Report Period:

If the setting is configured for 1hour (set value =720), the 
DOUBLE SWITCH will report its instant power consumption 
every 1 hour to the node of correspond Group. The maximum 
interval to report its instant power consumption is 45 hours 
(5s*32767/3600=45hr).

3-2 KWH Meter Report Period:

If the setting is configured for 1hour (set value =6), the DOU-
BLE SWITCH will report its Accumulated Power Consumption 
(KW/h) every 1 hour to the node of correspond Group. The 
maximum interval to report its Accumulated Power Consump-
tion (KW/h) is 227.55 days (10min*32767/1440=227.55 days).

3-3 Selected Relay

If Controller not using Multi_Channel command class to access 
the relay of DOUBLE SWITCH, you may configure the select 
value to react the Basic Command Class Binary Switch Com-
mand Class or Meter Command Class V3

3-3-1 Selected Relay1:

Only relay1 can be controlled and report.

3-3-2 Selected Relay 2:

Only relay2 can be controlled and report.

3-3-3 Selected Relay1 and Relay2: Default select is 3 

Both relay1 and relay2 can be controlled and report.

Get Command parameter

Raport to command sender

Meter Get

KWh

Relay1 KWh1+Relay2 KWh2

Meter Get

Watt

Relay1 W1+Relay2 W2

Meter Get

Voltage

Relay1 and Relay2 are the 
same voltage

Meter Get

Current

Relay1 I1+Relay2 I2

Meter Get

Power fac-
tor PF

Relay1

3-4 Edge and Pulse mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or 
Edge-Toggle mode, default value is Edge mode.

3-4-1 Edge mode:

 this mode is suitable for the bi stable wall 

switch that has indicator point on the switch, and the same 
position correspond to same state of relay1 and relay2. if the 
DOUBLE SWITCH relay change the state because of receiving 
Z-Wave RF command, it may need two times of change (switch 
on to off or switch off to on) to let relay back to the correspond 
state.

3-4-2 Pulse mode: 

this mode is suitable for the toggle type wall 

switch to swap the state of Relay1 or Relay2.

3-4-3 Edge-Toggle mode:

 this mode is suitable for the normal 

bi-stable switch, every time when change the state of the wall 
switch will also swap the state of Relay1 or Relay2.

3-5 Threshold of current for Load Caution

This is a warning when the current of load over the preset 
threshold value, if the setting value is 750, when the load cur-
rent of Relay1 or Relay2 over this value, DOUBLE SWITCH will 
send current meter report to the node of correspond Group, 
the Range of the setting value is from 10 to 750, and the default 
value is 750.

3-6 Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset thresh-
old value, If the setting value is 10000, when the Accumulated 
Power Consumption of Relay1 or Relay2 over this value, DOU-
BLE SWITCH will send KWh Meter Report command to the 
node of correspond Group, minimum value is 1KWh and default 
value is 10000 kWh.

3-7 Restore switch state mode

Whenever the AC power return from lost, DOUBLE SWITCH 
will restore the switch state which could be SWITCH OFF, LAST 
SWITCH STATE, SWITCH ON. The default setting is LAST 
SWITCH STATE.

3-8 Auto off timer:

Whenever DOUBLE SWITCH switches to on, the auto off timer 
begin to count down. After the timer decrease to zero, it will 
switch off automatically. However if Auto off timer is set as 0, 
the auto off function will be disabled. The default setting is 0.

3-9 RF off command mode

Whenever a switch off command, BASIC_SET BINARY_
SWITCH_SET SWITCH_ALL_OFF, is received, it could be inter-
preted as 4 kinds of commands.

3-9-1 Switch Off: It switches to OFF state. The default setting 
is Switch Off. 
3-9-2 Ignore: The switch off command will be ignored.
3-9-3 Switch Toggle: It switches to the inverse of current state. 
3-9-4 Switch On: It switches to ON state.

3-10 Existence of Endpoint3:

Multi-Channel Command is a good way to control relay1 and re-
lay2 of DOUBLE SWITCH individually. The endpoint3 of DOU-
BLE SWITCH is related to both relay1 and relay2. In some con-
dition it becomes redundant in Multi-Channel Command Class. 
When the Existence of Endpoint3 is set as 2, the endpoint3 will 
be disabled. The default value is 1.

Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.

4.Protection Command Classes

DOUBLE SWITCH supports Protection Command Class ver-
sion 2, it can protect the switch against unintentionally control 
by e.g. a child. And it can also protect the switch from being 
turned off by setting it in “No RF Control” state.

After being set to “Protection by sequence” state, any inten-
tional pressing of On/Off button or S2/S2 should be hold longer 
than 1 second, or the switch state will not change. However, the 
operation of learn function does not change, because learning 
will not be protected.

5. Firmware update over the air (OTA)

DOUBLE SWITCH is based on 500 series SoC and supports 
Firmware Update Command Class, it can receives the updated 
firmware image sent by controller via the Z-wave RF media. It 
is a helpful and convenient way to improve some functions if 
needed.

Troubleshooting

Symptom

Cause of failure

Recommendation

The Double Switch 
is not working and 
LED is off

1. The Switch is not
connected to the 
Main Power.
2. The Double 
Switch has broken 
down

1. Check power 
connections
2. Don’t open up 
the Double Switch 
and send it for 
repair.

The Double Switch 
LED is flashing, but 
can not control the 
ON/OFF Switch of 
the load attached

Check if the load 
connected into the 
Switch has its own 
ON/OFF switch

Set the ON/OFF 
switch of the load 
attached to ON 
Reffering to assem-
bly drawing, check 
if all conections are 
correct.

The Switch LED is 
flashing, but the 
Detector cannot 
control the Switch

1. Association not 
carried out.
2. Same frequency 
interference.

1. Carry out as-
sociation
2. Wait for a while 
to re-try

LED is flashing, but 
cannot control the 
Switch

Overload occurs

Remove the load 
attached or check 
max. load cannot 
exceed 6.5A

DIMENSIONS

 