Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command = 0x02
(Meter_Report = 0x02)
Parameter 1 = 0x21
(Scale Bit2 = 0, Rate Type =
0x01,Meter Type=0x01)
Parameter 2 = 0x34
(Precision = 1, Scale Bit1Bit0
= 0x02, Size = 4)
Parameter 3 = 0x00
Instant Power Consumption =
0x000003EA = 100.2W
Parameter 4 = 0x00
Parameter 5 = 0x03
Parameter 6 = 0xEA
2-3-5-3 Get load voltage V from endpoint:
Meter_GET example:
Source End Point = 0x05
(this is the endpoint of com-
mand inquirer, here we as-
sume endpoint is 5, if the
inquirer doesn’t support multi
Channel this value will be 0)
(Bit Destination End
Point = 0x03)
(Bit Address =0; Destination
End Point range1~3)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x01
(Meter_Get = 0x01)
Parameter 1 = 0x20
(Scale = V = 0x04)
DOUBLE SWITCH AC load Voltage report example:
Source End Point = 0x03
(Meter report = Endpoint3)
(Bit Destination End
Point = 0x05)
(Bit Address =0 ; Destination
End Point = command in-
quirer’s Endpoint value)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x02
(Meter_Report = 0x02)
Parameter 1 = 0xA1
(Scale Bit2 = 1, Rate Type =
0x01, Meter Type=0x01)
Parameter 2 = 0x22
(Precision = 1, Scale Bit1Bit0
= 0x00, Size = 2)
Parameter 3 = 0x09
Voltage = 0x0910 = 232.0V
Parameter 4 = 0x10
2-3-5-4 Get load current I from endpoint:
Meter_GET example:
Source End Point = 0x05
(this is the endpoint of
command inquirer, here we
assume endpoint is 5, if the
inquirer doesn’t support multi
Channel this value will be 0)
(Bit A Destination
End Point = 0x03)
(Bit Address =0;Destination
End Point range1~3)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x01
(Meter_Get = 0x01)
Parameter 1 = 0x28
(Scale = A = 0x05)
DOUBLE SWITCH AC load current (I) example:
Source End Point = 0x03
(Meter report = Endpoint3)
(Bit Destination End
Point = 0x05)
(Bit Address =0;Destination
End Point = command in-
quirer’s Endpoint value)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x02
(Meter_Report = 0x02)
Parameter 1 = 0xA1
(Scale Bit2 = 1, Rate Type =
0x01, Meter Type=0x01)
Parameter 2 = 0x4A
(Precision = 2, Scale Bit1Bit0
= 0x01, Size = 2)
Parameter 3 = 0x00
Current = 0x002B= 0.043A
Parameter 4 = 0x2B
Current = 0x002B= 0.043A
2-3-5-5 Get power factor PF from endpoint
Meter_GET example:
Source End Point = 0x05
(this is the endpoint of
command inquirer, here we
assume endpoint is 5, if the
inquirer doesn’t support multi
Channel thiS value will be 0)
(Bit Destination End
Point = 0x03)
(Bit Address =0;Destination
End Point range 1-3)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x01
(Meter_Get = 0x01)
Parameter 1 = 0x30
(Scale = PF = 0x06)
DOUBLE SWITCH power factor report example:
Source End Point = 0x03
(Meter report = Endpoint 3)
(Bit Destination End
Point = 0x05)
(Bit Address =0;Destination
End Point = command in-
quirer’s Endpoint value)
Command Class = 0x32
(Command_Class_Meter_V3
= 0x32)
Command =0x02
(Meter_Report = 0x02)
Parameter 1 = 0xA1
(Scale Bit2 = 1, Rate Type =
0x01,Meter Type=0x01)
Parameter 2 = 0x51
(Precision = 2, Scale Bit1Bit0
= 0x10, Size =1)
Parameter 3 = 0x63
Power Factor = 0x63 = 0.99
3. Z – Wave’s Configuration
Configuration
Parameter
Size (Byte)
Unit
Default
Function
Value
Description
1 Watt Me-
ter Report
Period
2 0x01-
0x7FFF
5s
720 720*5s=3600s=1
hour
2 KWH Me-
ter Report
Period
2 0x01-
0x7FFF
10min 6
6*10min= 1 hour
3 Selected
Relay
1 1-3
3
1:Relay 1
2:Relay 2
3:Relay 1 &
Relay 2
4 Edge or
Pulse mode
or Edge-
Toggle
mode
1 1-3
1
1:Edge mode
2:Pulse mode
3:Edge-Toggle
mode
5 Threshold
of current
for Load
Caution
2 10-750 0.01A 750 750*0.01A = 7.5A
6 Threshold
of KWH
for Load
Caution
2 1-
10000
1KWh 10
00
0
7 Restore
switch
state
mode
1 0-2
1
0 Swith off
1 Last switch
state
2 Switch on
8 Auto off
timer
2 0-0x
7FFF
1s
0
0 Disable auto off
function
1 0x7FFF 1s-
32767s
9 RF off
command
mode
1 0-3
0
0 Switch off
1 Ignore
2 Switch toggle
3 Switch on
10 Existance
of End-
point 3
1 1-2
1
1 Endpoint 3 exist
2 No Enpoint 3
3-1 Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), the
DOUBLE SWITCH will report its instant power consumption
every 1 hour to the node of correspond Group. The maximum
interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the DOU-
BLE SWITCH will report its Accumulated Power Consumption
(KW/h) every 1 hour to the node of correspond Group. The
maximum interval to report its Accumulated Power Consump-
tion (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
3-3 Selected Relay
If Controller not using Multi_Channel command class to access
the relay of DOUBLE SWITCH, you may configure the select
value to react the Basic Command Class Binary Switch Com-
mand Class or Meter Command Class V3
3-3-1 Selected Relay1:
Only relay1 can be controlled and report.
3-3-2 Selected Relay 2:
Only relay2 can be controlled and report.
3-3-3 Selected Relay1 and Relay2: Default select is 3
Both relay1 and relay2 can be controlled and report.
Get Command parameter
Raport to command sender
Meter Get
KWh
Relay1 KWh1+Relay2 KWh2
Meter Get
Watt
Relay1 W1+Relay2 W2
Meter Get
Voltage
Relay1 and Relay2 are the
same voltage
Meter Get
Current
Relay1 I1+Relay2 I2
Meter Get
Power fac-
tor PF
Relay1
3-4 Edge and Pulse mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or
Edge-Toggle mode, default value is Edge mode.
3-4-1 Edge mode:
this mode is suitable for the bi stable wall
switch that has indicator point on the switch, and the same
position correspond to same state of relay1 and relay2. if the
DOUBLE SWITCH relay change the state because of receiving
Z-Wave RF command, it may need two times of change (switch
on to off or switch off to on) to let relay back to the correspond
state.
3-4-2 Pulse mode:
this mode is suitable for the toggle type wall
switch to swap the state of Relay1 or Relay2.
3-4-3 Edge-Toggle mode:
this mode is suitable for the normal
bi-stable switch, every time when change the state of the wall
switch will also swap the state of Relay1 or Relay2.
3-5 Threshold of current for Load Caution
This is a warning when the current of load over the preset
threshold value, if the setting value is 750, when the load cur-
rent of Relay1 or Relay2 over this value, DOUBLE SWITCH will
send current meter report to the node of correspond Group,
the Range of the setting value is from 10 to 750, and the default
value is 750.
3-6 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset thresh-
old value, If the setting value is 10000, when the Accumulated
Power Consumption of Relay1 or Relay2 over this value, DOU-
BLE SWITCH will send KWh Meter Report command to the
node of correspond Group, minimum value is 1KWh and default
value is 10000 kWh.
3-7 Restore switch state mode
Whenever the AC power return from lost, DOUBLE SWITCH
will restore the switch state which could be SWITCH OFF, LAST
SWITCH STATE, SWITCH ON. The default setting is LAST
SWITCH STATE.
3-8 Auto off timer:
Whenever DOUBLE SWITCH switches to on, the auto off timer
begin to count down. After the timer decrease to zero, it will
switch off automatically. However if Auto off timer is set as 0,
the auto off function will be disabled. The default setting is 0.
3-9 RF off command mode
Whenever a switch off command, BASIC_SET BINARY_
SWITCH_SET SWITCH_ALL_OFF, is received, it could be inter-
preted as 4 kinds of commands.
3-9-1 Switch Off: It switches to OFF state. The default setting
is Switch Off.
3-9-2 Ignore: The switch off command will be ignored.
3-9-3 Switch Toggle: It switches to the inverse of current state.
3-9-4 Switch On: It switches to ON state.
3-10 Existence of Endpoint3:
Multi-Channel Command is a good way to control relay1 and re-
lay2 of DOUBLE SWITCH individually. The endpoint3 of DOU-
BLE SWITCH is related to both relay1 and relay2. In some con-
dition it becomes redundant in Multi-Channel Command Class.
When the Existence of Endpoint3 is set as 2, the endpoint3 will
be disabled. The default value is 1.
Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
4.Protection Command Classes
DOUBLE SWITCH supports Protection Command Class ver-
sion 2, it can protect the switch against unintentionally control
by e.g. a child. And it can also protect the switch from being
turned off by setting it in “No RF Control” state.
After being set to “Protection by sequence” state, any inten-
tional pressing of On/Off button or S2/S2 should be hold longer
than 1 second, or the switch state will not change. However, the
operation of learn function does not change, because learning
will not be protected.
5. Firmware update over the air (OTA)
DOUBLE SWITCH is based on 500 series SoC and supports
Firmware Update Command Class, it can receives the updated
firmware image sent by controller via the Z-wave RF media. It
is a helpful and convenient way to improve some functions if
needed.
Troubleshooting
Symptom
Cause of failure
Recommendation
The Double Switch
is not working and
LED is off
1. The Switch is not
connected to the
Main Power.
2. The Double
Switch has broken
down
1. Check power
connections
2. Don’t open up
the Double Switch
and send it for
repair.
The Double Switch
LED is flashing, but
can not control the
ON/OFF Switch of
the load attached
Check if the load
connected into the
Switch has its own
ON/OFF switch
Set the ON/OFF
switch of the load
attached to ON
Reffering to assem-
bly drawing, check
if all conections are
correct.
The Switch LED is
flashing, but the
Detector cannot
control the Switch
1. Association not
carried out.
2. Same frequency
interference.
1. Carry out as-
sociation
2. Wait for a while
to re-try
LED is flashing, but
cannot control the
Switch
Overload occurs
Remove the load
attached or check
max. load cannot
exceed 6.5A
DIMENSIONS