English
- 67 -
TUO Wi-Fi Chronothermostat User Manual
Operating hour meter
It displays the operating hours of the system (relay contacts on C-NA).
The device has two counters (5-digit)
independent for heating operation
and for the conditioning operation, but
is displayed only the counter of the
selected operation mode.
To reset the counter, keep the key
pressed for a long time during the display.
The maximum count is 65535h (about 7 years), when this digit is reached, the counter
resumes the count from 0h.
Display backlighting
The display backlighting can be:
• off (blue after pressing a key)
• fixed of a colour that can be chosen among
48
variants
• variable based on the difference between the
measured temperature and the set temperature:
- blue when the measured temperature is lower than the set temperature of at least
0.5°C (and after pressing a key)
- green when the difference between the measured temperature and the set one
is lower than 0.5°C (and in case of operation off)
- red when the measured temperature is higher than the set temperature
of at least 0.5 ° C
RII
colour 1 ..... colour 48
5*%
The backlighting can also be activated/deactivated from the initial screen by keeping
the key
pressed for a long time.