- 33 -
User Manual
Athena
English
P12
P13
TEMPERATURE PROGRAMMING
• Temperature control uses 4 independent setpoint levels for each control zone and for
summer and winter operation modes. Setpoint levels can be selected in this menu.
• When in this menu, which is marked by symbol
, , use arrow keys and
to select the temperature setpoint (T0, T1, T2 or T3) for the current zone and mode
(summer or winter) to be modified.
• Press
[OK]
to enter the temperature change (which will flash) and use arrow keys
and to change the value.
• Press
[OK]
to apply the change.
NOTE: when in summer operation mode temperature setpoint T0 cannot be
used, as it means air-conditioner OFF.
• The admitted temperature intervals are as follows:
Winter operation
Temperature
minimum [°C]
maximum [°C]
default
T0
2.0
T1
5.0
T1
T0
T2
15.0
T2
T1
T3
18.0
T3
T2
35.0
20.0
Summer operation
Setpoint
minimum setting
[°C]
maximum setting
[°C]
default
T0
-
-
OFF
T1
10
T1
23.0
T2
T1
T2
24.0
T3
T2
35.0
25.0
1
2
3
4
5
6
7
8
9
13 14 15 16 17 18 19 20 21 22 23
11 12
10
T1
T2
T3
1
2
3
4
5
6
7
8
9
13 14 15 16 17 18 19 20 21 22 23
11 12
10
T1
T2
T3