VEMCO - VR2AR / VR2AR-X Manual
15 March 2019
13
3.5
Select Transmitter Options
The transmitting option, which by default is enabled, can be setup to transmit depending on the usage you
have planned for the receiver. For example, if you are performing a range test, then select one of the Range
Test options. The ID transmitted was set at the time of manufacture and cannot be changed, but how often
the receiver transmits its code can be selected. Perform the steps listed below to setup the transmitter (and
enable, if currently not enabled).
Transmitter configuration defaults
ID
Set at manufacturing time, this unique identifier is not customizable.
Timing Profile
Default is “Sync Tag”
Power
Default is “Very High”
Enabled (checked)
Default is “Enabled”
NOTE:
If you have requested
different
default settings for your receiver(s),
consult your order Spec Sheet
.
Also, when you initialize your receiver (when starting a new study), the settings remain as you have selected
them here. The settings do not “reset” to the factory defaults.
Verify that the “enabled”
box contains a check
mark. If not, then select
it to enable the
transmitter. The
transmitting ID is shown
near the top of the
window.
STEP 2
Select the desired
Transmit Profile
from the drop-down
list based on the
descriptions at right.
This profile
determines how
often the VR2AR
will transmit its ID.
STEP 3
Range Test (random):
transmits
randomly between 60 to 120
seconds; nominal is 90 seconds
Range Test (90s):
transmits at a fixed
rate of 90 seconds
Sync Tag:
transmits randomly between
540 to 660 seconds; nominal is 600
seconds (10 minutes)
Click the gear shaped
icon in the VUE ribbon
and select Transmitter
Options to open the
Transmitter
Configuration
dialogue
box.
STEP 1
Continued…