43 VELUX
SECTION III: SOLAR CONTROL SYSTEM
SECTION III: SOLAR CONTROL SYSTEM
4.1.1 Indication of collector temperatures
Shows the current collector temperature.
• COL: Collector temperature (1-collector-system)
• COL1: Collector temperature 1
• COL2: Collector temperature 2
4.1.2 Indication of store temperatures
Shows the current store temperature.
• TST: Store temperature (1-store-system)
• TSTL: Store temperature lower
• TSTU: Store temperature above
• TST1: Temperature store 1
• TST2: Temperature store 2
4.1.3 Indication of sensor 3 and sensor 4
Shows the current temperature of the corresponding
additional sensor (without control function).
• S3: Temperature sensor 3
• S4: Temperature sensor 4
Please note:
S3 and S4 are only indicated if the
temperature sensors are connected.
4.1.4 Indication of other temperatures
Shows the current temperature of the
corresponding sensor.
• TFSB: Temperature solid fuel boiler
• TRET: Temperature heating reverse raising
• TRF: Temperature return flow
4.1.5 Indication of current pump speed
Shows the current pump speed of the
corresponding pump.
• n%: Current pump speed (1-pump-system)
• n1%: Current pump speed pump 1
• n2%: Current pump speed pump 2
COL / COL1 / COL2:
Collector temperature
Display range:
-40 ... +250°C
TST / TSTL / TSTU /
TST1 / TST2:
Store temperatures
Display range:
-40 ... +250°C
S3 / S4:
Sensor temperatures
Display range:
-40 ... +250°C
TFSB / TRET / TRF:
Other measuring
temperatures
Display range:
-40 ... +250°C
n% / n1% / n2%:
Current pump speed
Display range:
30 ... 100%